hmtsRegInterval
SCTE-HMS-HMTS-MIB ·
.1.3.6.1.4.1.5591.1.11.3.2.1.2.2.1
Object
scalar
r/w
1 s Integer32
This is the delay between the beginnings of each registration period. DEFAULT: vendor specific. This object is non-volatile.
Context
- MIB
- SCTE-HMS-HMTS-MIB
- OID
.1.3.6.1.4.1.5591.1.11.3.2.1.2.2.1- Type
- scalar
- Access
- readwrite
- Status
- current
- Units
- 1 s
- Parent
- hmtsRegistrationGroup
- Siblings
- 3
Syntax
1 s Integer32
Values & Constraints
Object Constraints
range: 1-86400
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hmtsRegMinDuration This is the minimum time for the registration
duration period. This is the minimum amount of time the
registration window will be open. Attempt to set minimum
duration greater … | scalar | 1 s Integer32 | .1.3.6.1.4.1.5591.1.11.3.2.1.2.2.2 |
| hmtsRegMaxDuration This is the maximum time for the registration duration
period. This is provided to allow a dynamic duration when a
large number of TALKRQST PDUs are received during registration
… | scalar | 1 s Integer32 | .1.3.6.1.4.1.5591.1.11.3.2.1.2.2.3 |
| hmtsRegContinuity This indicates the manner that the HMTS uses to handle
processing of the TALKRQST PDU for auto discovery.
immediate - means that the HMTS immediately terminates the
… | scalar | Enumeration | .1.3.6.1.4.1.5591.1.11.3.2.1.2.2.4 |