rcTinAndWinMsgAgingTime

RUGGEDCOM-SERIAL-MIB · .1.3.6.1.4.1.15004.4.6.6.6

Object

scalar r/w seconds Integer32
Aging time for TIN mode2 messages.
          
The feature is disabled if the value of this object is '0'.
          
When the feature is enabled, any TIN mode2 message received will be 
stored in an internal table. So if the same message is received 
within the time window specified by this parameter, the new message is 
considered duplicate, and thus discarded.

Context

MIB
RUGGEDCOM-SERIAL-MIB
OID
.1.3.6.1.4.1.15004.4.6.6.6
Type
scalar
Access
readwrite
Status
current
Units
seconds
Parent
rcTinAndWin
Siblings
11

Syntax

seconds Integer32

Values & Constraints

Object Constraints
range: 0-3600

Related Objects

Sibling Objects