rcIrigbPulseWidth1
RUGGEDCOM-IRIGB-MIB ·
.1.3.6.1.4.1.15004.4.10.1.12
Object
scalar
r/w
Integer32
Selects Pulse Width in ms for TTL output port. This parameter is used in conjunction with PPx to control the width of the pulse.
Context
- MIB
- RUGGEDCOM-IRIGB-MIB
- OID
.1.3.6.1.4.1.15004.4.10.1.12- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- rcIrigbBase
- Siblings
- 16
Syntax
Integer32
Values & Constraints
Object Constraints
range: 1-200
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| rcIrigbStatus The system synchronization status when IRIGB is a primary
time source.
If value of this object is changed, rcIrigbStatusChange notification
will be sent. | scalar | RUGGEDCOM-TIMECONFIG-MIBRcTimeSyncStatus | .1.3.6.1.4.1.15004.4.10.1.1 |
| rcIrigbOutputPWM1 Selects Operational mode of TTL output port. PWM mode complies with IRIG
Standard 200-04. PPx provides generic pulse per x second interface to
synchronize external devices. | scalar | Enumeration | .1.3.6.1.4.1.15004.4.10.1.10 |
| rcIrigbPulseInterval1 Selects Pulse Interval in s for TTL output port. This parameter is used
in conjunction with PPx in order to provides generic pulse per x second
interface to synchronize external d… | scalar | Integer32 | .1.3.6.1.4.1.15004.4.10.1.11 |
| rcIrigbStartTime1 This parameter is used in conjunction with PPx to set the starting time of
first PPx event. Note that this parameter must be set at least 15 seconds
before the start of desired P… | scalar | RcTimeStamp | .1.3.6.1.4.1.15004.4.10.1.13 |
| rcIrigbOutputPWM2 Selects Operational mode of TTL output port2. PWM mode complies with IRIG
Standard 200-04. PPx provides generic pulse per x second interface to
synchronize external devices. | scalar | Enumeration | .1.3.6.1.4.1.15004.4.10.1.14 |
| rcIrigbPulseInterval2 Selects Pulse Interval in s for TTL output port2. This parameter is used
in conjunction with PPx in order to provides generic pulse per x second
interface to synchronize external … | scalar | Integer32 | .1.3.6.1.4.1.15004.4.10.1.15 |
| rcIrigbPulseWidth2 Selects Pulse Width in ms for TTL output port2. This parameter is used in
conjunction with PPx to control the width of the pulse. | scalar | Integer32 | .1.3.6.1.4.1.15004.4.10.1.16 |
| rcIrigbStartTime2 This parameter is used in conjunction with PPx to set the starting time of
first PPx event. Note that this parameter must be set at least 15 seconds
before the start of desired P… | scalar | RcTimeStamp | .1.3.6.1.4.1.15004.4.10.1.17 |
| rcIrigbAMOutput Selects AM (Amplitude Modulation) mode of IRIGB port. | scalar | Enumeration | .1.3.6.1.4.1.15004.4.10.1.2 |
| rcIrigbTimeCode This device uses the following convention to decode the IRIGB time code:
letter [B] represents IRIG-B format, [xx] represents [00] for PWM/TTL mode
of operation and [12] for AM op… | scalar | Enumeration | .1.3.6.1.4.1.15004.4.10.1.3 |
| rcIrigbExt IRIGB extensions use extra bits of the Control Functions (CF) portion of the
IRIGB time code. Within this portion of the time code, bits are designated for
additional features, i… | scalar | Enumeration | .1.3.6.1.4.1.15004.4.10.1.4 |
| rcIrigbInput Selects operational mode of IRIGB input port. IRIGB module is capable of interpreting
IRIGB extensions such as C37.118-2011, C37.118-2005 and IEEE1344. | scalar | Enumeration | .1.3.6.1.4.1.15004.4.10.1.5 |
| rcIrigbLockInt To set time interval in minute with in which IRIGB receiver
should acquire lock to the time source.
Normally IRIGB receiver needs couple of minutes to lock
the signal.
Use… | scalar | Integer32 | .1.3.6.1.4.1.15004.4.10.1.6 |
| rcIrigbCableComp Cable compensation in ns may be desired to compensate for a long
cable run in order to minimize the timing inaccuracy. | scalar | Integer32 | .1.3.6.1.4.1.15004.4.10.1.7 |
| rcIrigbOFM The current time offset between system and reference clocks. | scalar | Integer32 | .1.3.6.1.4.1.15004.4.10.1.8 |
| rcIrigbFreqAdj The current amount of discipline applied to the local frequency reference (TCXO). | scalar | Integer32 | .1.3.6.1.4.1.15004.4.10.1.9 |