temperatureCompensation
RPS-SC300-MIB ·
.1.3.6.1.4.1.1918.2.14.10.70.20
Object
node
No description available.
Context
- MIB
- RPS-SC300-MIB
- OID
.1.3.6.1.4.1.1918.2.14.10.70.20- Type
- node
- Status
- current
- Parent
- controlFunctions
- Siblings
- 13
- Children
- 8
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| voltageControl | node | - | .1.3.6.1.4.1.1918.2.14.10.70.10 |
| resetAhDischarged This command resets controller battery state information (Amp hours discharged) and reverts all control process states to Inactive. | scalar | NoData | .1.3.6.1.4.1.1918.2.14.10.70.25 |
| ahDischargedFloatResetRate Once the battery has returned to float the Ah discharged figure is adjust towards zero by this factor multiplied by Battery-State-Threshold. In Solar applications where the amount… | scalar | 0.1 Float | .1.3.6.1.4.1.1918.2.14.10.70.27 |
| equalize | node | - | .1.3.6.1.4.1.1918.2.14.10.70.30 |
| fastCharge | node | - | .1.3.6.1.4.1.1918.2.14.10.70.40 |
| controlState Indicates the state of control process, e.g. Equalize, Fast Charge or Normal. | scalar | ControlState | .1.3.6.1.4.1.1918.2.14.10.70.5 |
| batteryCurrentLimit | node | - | .1.3.6.1.4.1.1918.2.14.10.70.50 |
| batteryTest | node | - | .1.3.6.1.4.1.1918.2.14.10.70.70 |
| lvd | node | - | .1.3.6.1.4.1.1918.2.14.10.70.75 |
| generatorControl | node | - | .1.3.6.1.4.1.1918.2.14.10.70.80 |
| peakLoadReduction | node | - | .1.3.6.1.4.1.1918.2.14.10.70.85 |
| energyMeters | node | - | .1.3.6.1.4.1.1918.2.14.10.70.87 |
| fanController | node | - | .1.3.6.1.4.1.1918.2.14.10.70.88 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| temperatureCompensationState The state of the Temperature Compensation process. To be active, it must be enabled, and the temperature sensor must be working. | scalar | TcState | .1.3.6.1.4.1.1918.2.14.10.70.20.10 |
| temperatureCompensationSlope Bus voltage adjustment rate. Use the value specified by the battery manufacturer. | scalar | 0.01 mV/°C/Cell Float | .1.3.6.1.4.1.1918.2.14.10.70.20.20 |
| temperatureCompensationReferenceTemperature The temperature where no voltage adjustment is applied. Use the value specified by the battery manufacturer. | scalar | 0.1 °C Float | .1.3.6.1.4.1.1918.2.14.10.70.20.30 |
| temperatureCompensationUpperLimit No additional voltage adjustment is made above this temperature. | scalar | 0.1 °C Float | .1.3.6.1.4.1.1918.2.14.10.70.20.40 |
| enableTemperatureCompensation When enabled, the battery charge voltage is automatically adjusted based on temperature. This is recommended by battery manufacturers to optimize battery life. | scalar | EnableState | .1.3.6.1.4.1.1918.2.14.10.70.20.5 |
| temperatureCompensationLowerLimit No additional voltage adjustment is made below this temperature. | scalar | 0.1 °C Float | .1.3.6.1.4.1.1918.2.14.10.70.20.50 |
| temperatureCompensationOffsetVoltage The adjustment to the bus voltage being applied due to the Temperature Compensation. Offset is zero when the battery temperature equals the reference temperature. | scalar | 0.01 V Float | .1.3.6.1.4.1.1918.2.14.10.70.20.60 |
| temperatureCompensationAllowed Indicates if Temperature Compensation is allowed to start or not. Temperature compensation cannot start if there are no rectifiers with AC power, or if the temperature sensor has … | scalar | CanStart | .1.3.6.1.4.1.1918.2.14.10.70.20.7 |