rectifierReportedVoltage
RPS-SC300-MIB ·
.1.3.6.1.4.1.1918.2.14.10.60.30.1.95
Object
column
0.01 V Float
The output voltage measured by this rectifier. This is measured by the rectifier and reported via the RXP bus.
Context
- MIB
- RPS-SC300-MIB
- OID
.1.3.6.1.4.1.1918.2.14.10.60.30.1.95- Type
- column
- Access
- readonly
- Status
- current
- Units
- 0.01 V
- Parent
- rectifierValuesEntry
- Table
- rectifierValuesTable
- Siblings
- 25
Syntax
0.01 V Float
- Source
- Float
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| rectifierValuesIndex Automatically generated index object. | column | Integer32 | .1.3.6.1.4.1.1918.2.14.10.60.30.1.1 |
| rectifierReportedCurrent The current produced by this rectifier. This is measured by the rectifier and reported via the rectifier comms bus. | column | A Float | .1.3.6.1.4.1.1918.2.14.10.60.30.1.100 |
| rectifierOutputPowerw The current rectifier output power as Watts. | column | W DcPower | .1.3.6.1.4.1.1918.2.14.10.60.30.1.103 |
| rectifierOutputPower The current rectifier output power as a percentage of the power limit under the current operating conditions. | column | 0.1 % Float | .1.3.6.1.4.1.1918.2.14.10.60.30.1.105 |
| rectifierHeatsinkTemperature The measured rectifier heatsink temperature. | column | °C Float | .1.3.6.1.4.1.1918.2.14.10.60.30.1.110 |
| rectifierRegistrationState Registration state of this rectifier. | column | RcpSlaveState | .1.3.6.1.4.1.1918.2.14.10.60.30.1.120 |
| rectifierFailedState A rectifier's failed state. | column | RectFailState | .1.3.6.1.4.1.1918.2.14.10.60.30.1.130 |
| loadBasedRunTime The time the rectifier has been operating since it was registered. | column | s TimeIntervalInSeconds | .1.3.6.1.4.1.1918.2.14.10.60.30.1.140 |
| shutdownRectifier Shuts down the rectifier or restarts it. Use Rectifier Has Been Shutdown to see whether the command has been sent to the rectifier since it can take some seconds. | column | Boolean | .1.3.6.1.4.1.1918.2.14.10.60.30.1.150 |
| rectifierHasBeenShutdown Indicates if the rectifier shutdown command has been sent. Once a Shutdown Rectifier command has been issued some time may elapse before the command is sent to the rectifier. Rect… | column | Boolean | .1.3.6.1.4.1.1918.2.14.10.60.30.1.160 |
| rectifierPhase1 Rectifier's AC voltage measured at the input connection for phase 1. | column | V Float | .1.3.6.1.4.1.1918.2.14.10.60.30.1.170 |
| rectifierPhase2 Rectifier's AC voltage measured at the input connection for phase 2. | column | V Float | .1.3.6.1.4.1.1918.2.14.10.60.30.1.180 |
| rectifierPhase3 Rectifier's AC voltage measured at the input connection for phase 3. | column | V Float | .1.3.6.1.4.1.1918.2.14.10.60.30.1.190 |
| rectifierNotes This text will not be valid if the rectifier is unplugged and is not permanently stored by the controller. | column | OctetString | .1.3.6.1.4.1.1918.2.14.10.60.30.1.200 |
| rectifierInputCurrent The input current measured by the rectifier (AC) or Solar (DC). | column | A Float | .1.3.6.1.4.1.1918.2.14.10.60.30.1.210 |
| rectifierPhase This rectifiers AC phase. The controller is unable to determine which supply is used on a dual feed supply | column | AcPhase | .1.3.6.1.4.1.1918.2.14.10.60.30.1.220 |
| rectifierSerialNumber Rectifier serial number. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1918.2.14.10.60.30.1.30 |
| rectifierType Rectifier Type. | column | OctetString | .1.3.6.1.4.1.1918.2.14.10.60.30.1.40 |
| rectifierInputType Rectifier Input Type, regular rectifier is AC, Solar Charger is MPPT. | column | InputType | .1.3.6.1.4.1.1918.2.14.10.60.30.1.50 |
| rectifierStatus The status reported by this rectifier. This value cannot be interpreted without knowing the meaning of the various status bits. This is documented in the RXP command set for recti… | column | Unsigned8 | .1.3.6.1.4.1.1918.2.14.10.60.30.1.60 |
| rectifierMaximumCurrentLimit The current limit value of the rectifier. Adjust Rectifier Current Limit to set a lower operating current limit. | column | A Unsigned8 | .1.3.6.1.4.1.1918.2.14.10.60.30.1.70 |
| rectifierMaximumPowerLimit The maximum output power limit value of the rectifier. Adjust Rectifier Current Limit to set a lower operating power limit. | column | W DcPower | .1.3.6.1.4.1.1918.2.14.10.60.30.1.80 |
| rectifierMinimumOvsdSetPoint The minimum OVSD set point that the rectifier accepts. | column | 0.01 V Float | .1.3.6.1.4.1.1918.2.14.10.60.30.1.83 |
| rectifierMaximumOvsdSetPoint The maximum OVSD set point that the rectifier accepts. | column | 0.01 V Float | .1.3.6.1.4.1.1918.2.14.10.60.30.1.86 |
| rectifierInputVoltage The input voltage measured by the rectifier (AC) or Solar (DC). | column | V Float | .1.3.6.1.4.1.1918.2.14.10.60.30.1.90 |