lowDoMappingA
RPS-SC300-MIB ·
.1.3.6.1.4.1.1918.2.14.10.90.10.30.1.200
Object
column
r/w
RelayMapping
Optional digital output activated while this alarm is active.
Context
- MIB
- RPS-SC300-MIB
- OID
.1.3.6.1.4.1.1918.2.14.10.90.10.30.1.200- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- analogInputEntry
- Table
- analogInputTable
- Siblings
- 26
Syntax
RelayMapping
- Source
- RelayMapping
- Base type
Enumeration
Values & Constraints
Type Values
0 | none |
1 | digitalOutput1 |
2 | digitalOutput2 |
3 | digitalOutput3 |
4 | digitalOutput4 |
5 | digitalOutput5 |
6 | digitalOutput6 |
7 | digitalOutput7 |
8 | digitalOutput8 |
9 | digitalOutput9 |
10 | digitalOutput10 |
11 | digitalOutput11 |
12 | digitalOutput12 |
13 | digitalOutput13 |
14 | digitalOutput14 |
15 | digitalOutput15 |
16 | digitalOutput16 |
17 | digitalOutput17 |
18 | digitalOutput18 |
19 | digitalOutput19 |
20 | digitalOutput20 |
21 | digitalOutput21 |
22 | digitalOutput22 |
23 | digitalOutput23 |
24 | digitalOutput24 |
25 | digitalOutput25 |
26 | digitalOutput26 |
27 | digitalOutput27 |
28 | digitalOutput28 |
29 | digitalOutput29 |
30 | digitalOutput30 |
31 | digitalOutput31 |
32 | digitalOutput32 |
33 | digitalOutput33 |
34 | digitalOutput34 |
35 | digitalOutput35 |
36 | digitalOutput36 |
37 | digitalOutput37 |
38 | digitalOutput38 |
39 | digitalOutput39 |
40 | digitalOutput40 |
41 | digitalOutput41 |
42 | digitalOutput42 |
43 | digitalOutput43 |
44 | digitalOutput44 |
45 | digitalOutput45 |
46 | digitalOutput46 |
47 | digitalOutput47 |
48 | digitalOutput48 |
49 | digitalOutput49 |
50 | digitalOutput50 |
51 | digitalOutput51 |
52 | digitalOutput52 |
53 | digitalOutput53 |
54 | digitalOutput54 |
55 | digitalOutput55 |
56 | digitalOutput56 |
57 | digitalOutput57 |
58 | digitalOutput58 |
59 | digitalOutput59 |
60 | digitalOutput60 |
61 | digitalOutput61 |
62 | digitalOutput62 |
63 | digitalOutput63 |
64 | digitalOutput64 |
65 | digitalOutput65 |
66 | digitalOutput66 |
67 | digitalOutput67 |
68 | digitalOutput68 |
69 | digitalOutput69 |
70 | digitalOutput70 |
71 | digitalOutput71 |
72 | digitalOutput72 |
73 | digitalOutput73 |
74 | digitalOutput74 |
75 | digitalOutput75 |
76 | digitalOutput76 |
77 | digitalOutput77 |
78 | digitalOutput78 |
79 | digitalOutput79 |
80 | digitalOutput80 |
81 | digitalOutput81 |
82 | digitalOutput82 |
83 | digitalOutput83 |
84 | digitalOutput84 |
85 | digitalOutput85 |
86 | digitalOutput86 |
87 | digitalOutput87 |
88 | digitalOutput88 |
89 | digitalOutput89 |
90 | digitalOutput90 |
91 | digitalOutput91 |
92 | digitalOutput92 |
93 | digitalOutput93 |
94 | digitalOutput94 |
95 | digitalOutput95 |
96 | digitalOutput96 |
97 | digitalOutput97 |
98 | digitalOutput98 |
99 | digitalOutput99 |
100 | digitalOutput100 |
101 | digitalOutput101 |
102 | digitalOutput102 |
103 | digitalOutput103 |
104 | digitalOutput104 |
105 | digitalOutput105 |
106 | digitalOutput106 |
107 | digitalOutput107 |
108 | digitalOutput108 |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| analogInputIndex Automatically generated index object. | column | Integer32 | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.1 |
| gain The scaling factor applied to the raw value read from the I/O board. | column | 0.01 Float | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.100 |
| offset The offset applied to the raw value read from the I/O board. | column | 0.01 Float | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.110 |
| hysteresis The amount of hysteresis applied to the input before an active alarm is deactivated. | column | 0.01 Float | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.130 |
| highSeverity The severity level associated with the alarm. Control alarms are not displayed, although any configured digital outputs are still activated. | column | AlarmSeverity | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.141 |
| highThreshold An analog input high alarm is activated if the scaled input is greater than or equal to this value. | column | 0.01 Float | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.150 |
| highDoMappingA Optional digital output activated while this alarm is active. | column | RelayMapping | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.160 |
| highDoMappingB Optional digital output activated while this alarm is active. | column | RelayMapping | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.170 |
| highTrapSend If set to true an SNMP trap is sent to every trap receiver with an appropriate trap level whenever this alarm changes state. | column | SendTrap | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.175 |
| lowSeverity The severity level associated with the alarm. Control alarms are not displayed, although any configured digital outputs are still activated. | column | AlarmSeverity | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.181 |
| lowThreshold An analog input low alarm is activated if the scaled input is lower than or equal to this value. | column | 0.01 Float | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.190 |
| aiHighState The state of the selected analog input high alarm. | column | AlarmActiveState | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.20 |
| lowDoMappingB Optional digital output activated while this alarm is active. | column | RelayMapping | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.210 |
| lowTrapSend If set to true an SNMP trap is sent to every trap receiver with an appropriate trap level whenever this alarm changes state. | column | SendTrap | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.215 |
| aiGroup The group tag used by software to group related inputs and outputs for display purposes. | column | Unsigned8 | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.220 |
| aiHighNotes User notes about this alarm. These notes appear in SNMP traps and can be viewed using DCTools or PowerManagerII. | column | OctetString | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.230 |
| aiLowNotes User notes about this alarm. These notes appear in SNMP traps and can be viewed using DCTools or PowerManagerII. | column | OctetString | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.240 |
| aiLowState The state of the selected analog input low alarm. | column | AlarmActiveState | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.30 |
| aiValue Analog input value. | column | 0.01 Float | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.40 |
| aiStatus Enable/disable this analog input channel. | column | EnableState | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.50 |
| aiName The name of this analog input channel as it will appear on management software such as DCTools or PowerManagerII. This name is not displayed on the controller. | column | OctetString | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.60 |
| aiFunction Selects how the value of this analog input is to be used by any control functions, if at all. | column | AiFunction | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.64 |
| aiFunctionIndex Select an index for the selected function. Only valid where function is Smart-Analog, Battery-Symmetry-Monitoring and Fan-Temperature. | column | Unsigned8 | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.66 |
| aiUnits Units of this analog input (after scaling). | column | MeasurementUnits | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.70 |
| aiIobNumber The I/O board number on which this analog input is located. | column | Unsigned8 | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.80 |
| inputNumber The input channel on the I/O board of this analog input. | column | Unsigned8 | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.90 |