log
RPS-SC300-MIB ·
.1.3.6.1.4.1.1918.2.14.10.107
Object
node
No description available.
Context
- MIB
- RPS-SC300-MIB
- OID
.1.3.6.1.4.1.1918.2.14.10.107- Type
- node
- Status
- current
- Parent
- rpsObjects
- Siblings
- 17
- Children
- 7
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| systemIdentity | node | - | .1.3.6.1.4.1.1918.2.14.10.10 |
| battery | node | - | .1.3.6.1.4.1.1918.2.14.10.100 |
| solar | node | - | .1.3.6.1.4.1.1918.2.14.10.105 |
| dcdc | node | - | .1.3.6.1.4.1.1918.2.14.10.106 |
| internal | node | - | .1.3.6.1.4.1.1918.2.14.10.108 |
| alarms | node | - | .1.3.6.1.4.1.1918.2.14.10.110 |
| trap700Bindings | node | - | .1.3.6.1.4.1.1918.2.14.10.111 |
| controller | node | - | .1.3.6.1.4.1.1918.2.14.10.20 |
| communications | node | - | .1.3.6.1.4.1.1918.2.14.10.30 |
| accessControl | node | - | .1.3.6.1.4.1.1918.2.14.10.33 |
| acInput | node | - | .1.3.6.1.4.1.1918.2.14.10.40 |
| dcOutput | node | - | .1.3.6.1.4.1.1918.2.14.10.50 |
| rxp | node | - | .1.3.6.1.4.1.1918.2.14.10.55 |
| rectifiers | node | - | .1.3.6.1.4.1.1918.2.14.10.60 |
| controlFunctions | node | - | .1.3.6.1.4.1.1918.2.14.10.70 |
| realTimeClock | node | - | .1.3.6.1.4.1.1918.2.14.10.80 |
| inputOutput | node | - | .1.3.6.1.4.1.1918.2.14.10.90 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| logFillMonths The maximum number of months that the log can hold. When full the log drops the oldest 4 kB of records. It assumes the bus voltage is never 'off-normal' and the number of events h… | scalar | Unsigned16 | .1.3.6.1.4.1.1918.2.14.10.107.10 |
| logUsed All Logs are written to the one file. This is the size in bytes of this file. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1918.2.14.10.107.20 |
| logItemsTable Table for logItems | table | - | .1.3.6.1.4.1.1918.2.14.10.107.40 |
| offNormalInterval The time between each log record when The off normal conditions are met. Smart alarm active or voltage offset active. A value of 0 disables off normal logging. | scalar | s TimeIntervalInSeconds | .1.3.6.1.4.1.1918.2.14.10.107.50 |
| offNormalOffsetVoltage The Off Normal Log Interval will apply when bus voltage is outside the range: float voltage ± Off Normal Log Offset. Off normal condition transitions is recognized within 10 secon… | scalar | 0.01 V Float | .1.3.6.1.4.1.1918.2.14.10.107.60 |
| offNormalSmartAlarm While this Smart Alarm is active logs are off normal. | scalar | Unsigned8 | .1.3.6.1.4.1.1918.2.14.10.107.70 |
| isOffNormal Indicates which log interval is used. | scalar | Boolean | .1.3.6.1.4.1.1918.2.14.10.107.80 |