enableActiveVoltageControl
RPS-SC300-MIB ·
.1.3.6.1.4.1.1918.2.14.10.70.10.35
Object
scalar
r/w
EnableState
When AVC is enabled the rectifier output voltage is adjusted to maintain the bus voltage at the configured float voltage (plus or minus any adjustments by active control processes) within a predefined dead band. Enable AVC unless there is specific reason to disable.
Context
- MIB
- RPS-SC300-MIB
- OID
.1.3.6.1.4.1.1918.2.14.10.70.10.35- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- voltageControl
- Siblings
- 11
Syntax
EnableState
- Source
- EnableState
- Base type
Enumeration
Values & Constraints
Type Values
0 | disabled |
1 | enabled |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| floatVoltage The voltage required to maintain optimum battery charge (at the nominal ambient temperature). Use the value recommended by the battery manufacturer. The bus voltage may be adjuste… | scalar | 0.01 V Float | .1.3.6.1.4.1.1918.2.14.10.70.10.10 |
| alternativeFloatVoltage When Alternative-Charge is operating it will charge float at this voltage. | scalar | 0.01 V Float | .1.3.6.1.4.1.1918.2.14.10.70.10.11 |
| alternativeFloatSmartAlarm The smart alarm that will enable float charging at Alternative-Float-Voltage instead of Float-Voltage. | scalar | Unsigned8 | .1.3.6.1.4.1.1918.2.14.10.70.10.12 |
| alternativeFloatStatus Indicates the state of Alternative-Float-Voltage: Disabled, Inactive, or Active (currently being used instead of Float-Voltage). | scalar | ControlProcessState | .1.3.6.1.4.1.1918.2.14.10.70.10.13 |
| maximumSystemVoltage Many control functions adjust the bus voltage depending on their respective conditions. However, under no circumstances will the controller deliberately exceed this value. A faili… | scalar | 0.01 V Float | .1.3.6.1.4.1.1918.2.14.10.70.10.15 |
| minimumSystemVoltage Many control functions adjust the bus voltage depending on their respective conditions. However, under no circumstances will the controller deliberately adjust the bus voltage to … | scalar | 0.01 V Float | .1.3.6.1.4.1.1918.2.14.10.70.10.17 |
| busVoltage The system bus voltage from the bus voltage sensor. If the bus voltage sensor has failed, the system bus voltage is determined from the rectifier output voltages. | scalar | 0.01 V Float | .1.3.6.1.4.1.1918.2.14.10.70.10.20 |
| targetVoltage The voltage maintained by AVC. AVC will set the Base Voltage to attempt to maintain the bus voltage to this value. | scalar | 0.01 V Float | .1.3.6.1.4.1.1918.2.14.10.70.10.30 |
| avcState The state of the Active Voltage Control (AVC) process. | scalar | AvcState | .1.3.6.1.4.1.1918.2.14.10.70.10.40 |
| avcOffset The difference between the Target Voltage and the measured bus voltage. | scalar | 0.01 V Float | .1.3.6.1.4.1.1918.2.14.10.70.10.50 |
| baseVoltage The voltage sent to the rectifiers. This is the Target Voltage plus the AVC Offset. | scalar | 0.01 V Float | .1.3.6.1.4.1.1918.2.14.10.70.10.60 |