digitalInputNumber
RPS-SC300-MIB ·
.1.3.6.1.4.1.1918.2.14.10.90.40.1.70
Object
column
r/w
Unsigned8
The input channel on the I/O board of this digital input.
Context
- MIB
- RPS-SC300-MIB
- OID
.1.3.6.1.4.1.1918.2.14.10.90.40.1.70- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- digitalInputEntry
- Table
- digitalInputTable
- Siblings
- 15
Syntax
Unsigned8
- Source
- Unsigned8
- Base type
Integer32
Values & Constraints
Type Constraints
range: 0..255
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| digitalInputIndex Automatically generated index object. | column | Integer32 | .1.3.6.1.4.1.1918.2.14.10.90.40.1.1 |
| diDoMappingB Optional digital output activated while this digital input alarm is active. | column | RelayMapping | .1.3.6.1.4.1.1918.2.14.10.90.40.1.100 |
| diTrapSend If set to true an SNMP trap is sent to every trap receiver with an appropriate trap level whenever this alarm changes state. | column | SendTrap | .1.3.6.1.4.1.1918.2.14.10.90.40.1.105 |
| diActiveState Selects whether the input should be considered active when closed or open. | column | ActiveState | .1.3.6.1.4.1.1918.2.14.10.90.40.1.110 |
| diGroup The group tag used by software to group related inputs and outputs for display purposes. | column | Unsigned8 | .1.3.6.1.4.1.1918.2.14.10.90.40.1.120 |
| diNotes User notes about this alarm. These notes appear in SNMP traps and can be viewed using DCTools or PowerManagerII. | column | OctetString | .1.3.6.1.4.1.1918.2.14.10.90.40.1.130 |
| diState The state of this digital input alarm. | column | AlarmActiveState | .1.3.6.1.4.1.1918.2.14.10.90.40.1.20 |
| diValue The state of this digital input. | column | DigitalInputState | .1.3.6.1.4.1.1918.2.14.10.90.40.1.30 |
| diStatus Enable/disable this digital input channel. | column | EnableState | .1.3.6.1.4.1.1918.2.14.10.90.40.1.40 |
| diName The name of the digital input. | column | OctetString | .1.3.6.1.4.1.1918.2.14.10.90.40.1.50 |
| diIobNumber The I/O board number on which this digital input is located. | column | Unsigned8 | .1.3.6.1.4.1.1918.2.14.10.90.40.1.60 |
| diSeverity The severity level associated with the alarm. Control alarms are not displayed, although any configured digital outputs are still activated. | column | AlarmSeverity | .1.3.6.1.4.1.1918.2.14.10.90.40.1.81 |
| diRecognitionPeriod A digital input alarm will become active if the input is in the active state for the recognition time. | column | s TimeIntervalInSeconds | .1.3.6.1.4.1.1918.2.14.10.90.40.1.85 |
| diDeactivationRecognitionPeriod A digital input alarm will deactivate if the input is in the inactive state for the deactivation recognition time. | column | s TimeIntervalInSeconds | .1.3.6.1.4.1.1918.2.14.10.90.40.1.86 |
| diDoMappingA Optional digital output activated while this digital input alarm is active. | column | RelayMapping | .1.3.6.1.4.1.1918.2.14.10.90.40.1.90 |