controller
RPS-SC300-MIB ·
.1.3.6.1.4.1.1918.2.14.10.20
Object
node
No description available.
Context
- MIB
- RPS-SC300-MIB
- OID
.1.3.6.1.4.1.1918.2.14.10.20- Type
- node
- Status
- current
- Parent
- rpsObjects
- Siblings
- 17
- Children
- 13
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| systemIdentity | node | - | .1.3.6.1.4.1.1918.2.14.10.10 |
| battery | node | - | .1.3.6.1.4.1.1918.2.14.10.100 |
| solar | node | - | .1.3.6.1.4.1.1918.2.14.10.105 |
| dcdc | node | - | .1.3.6.1.4.1.1918.2.14.10.106 |
| log | node | - | .1.3.6.1.4.1.1918.2.14.10.107 |
| internal | node | - | .1.3.6.1.4.1.1918.2.14.10.108 |
| alarms | node | - | .1.3.6.1.4.1.1918.2.14.10.110 |
| trap700Bindings | node | - | .1.3.6.1.4.1.1918.2.14.10.111 |
| communications | node | - | .1.3.6.1.4.1.1918.2.14.10.30 |
| accessControl | node | - | .1.3.6.1.4.1.1918.2.14.10.33 |
| acInput | node | - | .1.3.6.1.4.1.1918.2.14.10.40 |
| dcOutput | node | - | .1.3.6.1.4.1.1918.2.14.10.50 |
| rxp | node | - | .1.3.6.1.4.1.1918.2.14.10.55 |
| rectifiers | node | - | .1.3.6.1.4.1.1918.2.14.10.60 |
| controlFunctions | node | - | .1.3.6.1.4.1.1918.2.14.10.70 |
| realTimeClock | node | - | .1.3.6.1.4.1.1918.2.14.10.80 |
| inputOutput | node | - | .1.3.6.1.4.1.1918.2.14.10.90 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| manufacturerName The name of the manufacturer. | scalar | OctetString | .1.3.6.1.4.1.1918.2.14.10.20.10 |
| ethernetMacAddress The unique ethernet address of the controller. | scalar | OctetString | .1.3.6.1.4.1.1918.2.14.10.20.100 |
| subversionRevision The software build number. | scalar | OctetString | .1.3.6.1.4.1.1918.2.14.10.20.110 |
| evaluationSoftwareFound The Software currently installed is for evaluation purposes and is not for sale. | scalar | Boolean | .1.3.6.1.4.1.1918.2.14.10.20.120 |
| genericSystemType Choices any System type other than unknown will change configuration to installation defaults for that system | scalar | GenericSystemType | .1.3.6.1.4.1.1918.2.14.10.20.150 |
| productType Mandatory command identifying the device. | scalar | ProductType | .1.3.6.1.4.1.1918.2.14.10.20.20 |
| softwareVersion Application software version. This is the software version of the main controller application. | scalar | OctetString | .1.3.6.1.4.1.1918.2.14.10.20.30 |
| bootVersion Bootloader software version. The bootloader is responsible for loading and running the system support software and the main application. The bootloader software can be upgrading u… | scalar | OctetString | .1.3.6.1.4.1.1918.2.14.10.20.50 |
| interfaceVersion S3P interface version. As the embedded software is upgraded, the communications interface may change. This number reflects any such change. This value, along with Compatible Inter… | scalar | Unsigned16 | .1.3.6.1.4.1.1918.2.14.10.20.70 |
| hardwareVersion The Product Hardware Version | scalar | OctetString | .1.3.6.1.4.1.1918.2.14.10.20.80 |
| lcdVersion The Product Hardware LCD Version | scalar | OctetString | .1.3.6.1.4.1.1918.2.14.10.20.82 |
| batteryMonitor The internal RTC battery health (100% = 3.81V). The battery health is measure once, each 48 hours. A low battery alarm triggers when <90% (<3.4V). | scalar | % Percentile8Nan | .1.3.6.1.4.1.1918.2.14.10.20.83 |
| serialNumber The Product Serial Number. This item is not reset by the Reset System Configuration command. | scalar | OctetString | .1.3.6.1.4.1.1918.2.14.10.20.90 |