batteryTimeRemaining
RPS-SC300-MIB ·
.1.3.6.1.4.1.1918.2.14.10.100.60
Object
node
No description available.
Context
- MIB
- RPS-SC300-MIB
- OID
.1.3.6.1.4.1.1918.2.14.10.100.60- Type
- node
- Status
- current
- Parent
- battery
- Siblings
- 14
- Children
- 13
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| batteryCapacity The rated 10-hour (C10) capacity of the battery. 0 = no battery is installed. | scalar | Ah SNMPv2-SMIInteger32 | .1.3.6.1.4.1.1918.2.14.10.100.10 |
| cellsPerString The number of 2V battery cells per string. Zero means no battery is installed. | scalar | Unsigned8 | .1.3.6.1.4.1.1918.2.14.10.100.20 |
| batteryTemperature The average of all analog inputs configured as battery temperature inputs. | scalar | °C Float | .1.3.6.1.4.1.1918.2.14.10.100.30 |
| batteryCurrent The total current flowing to/from the batteries. If positive, the battery is being charged. This value may be measured by the battery current shunt(s) if present or calculated fro… | scalar | A Float | .1.3.6.1.4.1.1918.2.14.10.100.40 |
| batteryType The name or type of the battery. | scalar | OctetString | .1.3.6.1.4.1.1918.2.14.10.100.42 |
| btrTimeRemaining An estimate of the time remaining until the average cell discharge voltage reaches the configured end voltage. This value is only available during a discharge if the battery has b… | scalar | min TimeIntervalInMinutes | .1.3.6.1.4.1.1918.2.14.10.100.43 |
| btrStateOfHealth The health of the battery measured as the estimated C10 capacity at the end of the last discharge as a percentage of the configured capacity. The accuracy of this value depends on… | scalar | % Percentile8Nan | .1.3.6.1.4.1.1918.2.14.10.100.44 |
| batteryChargeState Indicates the current state of the battery. | scalar | BatteryChargeState | .1.3.6.1.4.1.1918.2.14.10.100.45 |
| batteryStateThreshold The threshold used to determine the battery state. If the battery current is greater than the value, the battery state is Charge. If the battery current is less than the negative … | scalar | 0.1 A Float | .1.3.6.1.4.1.1918.2.14.10.100.47 |
| endOfChargeAction To ensure that there is no residual AhD error at the end of the charge, AhD can be set to zero after each charge. For new installations, Set Ah Discharged to zero after Equalize a… | scalar | EndOfChargeAction | .1.3.6.1.4.1.1918.2.14.10.100.48 |
| batteryDesign | node | - | .1.3.6.1.4.1.1918.2.14.10.100.49 |
| midPointMonitoring | node | - | .1.3.6.1.4.1.1918.2.14.10.100.50 |
| batteryCharacterizationDataTable Table for batteryCharacterizationData | table | - | .1.3.6.1.4.1.1918.2.14.10.100.62 |
| siteBackupTimeSettings | node | - | .1.3.6.1.4.1.1918.2.14.10.100.65 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| btrState The state of the battery time remaining algorithm. | scalar | BtrState | .1.3.6.1.4.1.1918.2.14.10.100.60.10 |
| btrStopBatteryCharacterization Stops the current battery characterization discharge. | scalar | NoData | .1.3.6.1.4.1.1918.2.14.10.100.60.100 |
| btrCancelWaiting Cancel the waiting period, returning the LVDs to automatic operation. | scalar | NoData | .1.3.6.1.4.1.1918.2.14.10.100.60.105 |
| btrClearBatteryCharacterization Clears the battery characterization data. It is recommended to make a backup of the characterization data first. | scalar | NoData | .1.3.6.1.4.1.1918.2.14.10.100.60.110 |
| batteryCharacterizationInstantaneousQuality During battery characterization this is the power variation from the desired controlled power. Greater than 90% is excepted. Lower values may make the characterization less useful… | scalar | % Percentile8Nan | .1.3.6.1.4.1.1918.2.14.10.100.60.120 |
| btrEndVoltage During a discharge the controller will provide an estimate of the time remaining until the average cell discharge voltage reaches this value. | scalar | 0.01 V/Cell Float | .1.3.6.1.4.1.1918.2.14.10.100.60.20 |
| btrCharacterizationEndVoltage The end voltage that the battery was last characterized to. For the controller to be able to estimate a remaining time, this value must be below the configured end voltage. | scalar | 0.01 V/Cell Float | .1.3.6.1.4.1.1918.2.14.10.100.60.30 |
| btrCharacterizationResult Indicates the result of the last characterization. | scalar | BtrCharacterizationResult | .1.3.6.1.4.1.1918.2.14.10.100.60.40 |
| btrCharacterizationTime End time of the last characterization. | scalar | JulianDateUtc25 | .1.3.6.1.4.1.1918.2.14.10.100.60.50 |
| btrAutomaticCharacterization If enabled, the controller will automatically perform a characterization when all necessary conditions have been met for the characterization delay. If the characterization fails,… | scalar | EnableState | .1.3.6.1.4.1.1918.2.14.10.100.60.60 |
| btrCharacterizationDelay If automatic characterization is enabled, the controller will automatically perform a battery characterization discharge when all conditions have been met for this time. | scalar | min TimeIntervalInMinutes | .1.3.6.1.4.1.1918.2.14.10.100.60.70 |
| btrCharacterizationStart If automatic characterization is enabled and all conditions for a characterization are met, this will indicate the remaining time until the automatic characterization discharge wi… | scalar | s TimeIntervalInSeconds | .1.3.6.1.4.1.1918.2.14.10.100.60.80 |
| btrCharacterizeBattery This will cause the controller to discharge the battery at a constant rate until the average cell discharge voltage reaches the configured end voltage. | scalar | NoData | .1.3.6.1.4.1.1918.2.14.10.100.60.90 |