batteryCurrentLimit
RPS-SC300-MIB ·
.1.3.6.1.4.1.1918.2.14.10.70.50
Object
node
No description available.
Context
- MIB
- RPS-SC300-MIB
- OID
.1.3.6.1.4.1.1918.2.14.10.70.50- Type
- node
- Status
- current
- Parent
- controlFunctions
- Siblings
- 13
- Children
- 5
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| voltageControl | node | - | .1.3.6.1.4.1.1918.2.14.10.70.10 |
| temperatureCompensation | node | - | .1.3.6.1.4.1.1918.2.14.10.70.20 |
| resetAhDischarged This command resets controller battery state information (Amp hours discharged) and reverts all control process states to Inactive. | scalar | NoData | .1.3.6.1.4.1.1918.2.14.10.70.25 |
| ahDischargedFloatResetRate Once the battery has returned to float the Ah discharged figure is adjust towards zero by this factor multiplied by Battery-State-Threshold. In Solar applications where the amount… | scalar | 0.1 Float | .1.3.6.1.4.1.1918.2.14.10.70.27 |
| equalize | node | - | .1.3.6.1.4.1.1918.2.14.10.70.30 |
| fastCharge | node | - | .1.3.6.1.4.1.1918.2.14.10.70.40 |
| controlState Indicates the state of control process, e.g. Equalize, Fast Charge or Normal. | scalar | ControlState | .1.3.6.1.4.1.1918.2.14.10.70.5 |
| batteryTest | node | - | .1.3.6.1.4.1.1918.2.14.10.70.70 |
| lvd | node | - | .1.3.6.1.4.1.1918.2.14.10.70.75 |
| generatorControl | node | - | .1.3.6.1.4.1.1918.2.14.10.70.80 |
| peakLoadReduction | node | - | .1.3.6.1.4.1.1918.2.14.10.70.85 |
| energyMeters | node | - | .1.3.6.1.4.1.1918.2.14.10.70.87 |
| fanController | node | - | .1.3.6.1.4.1.1918.2.14.10.70.88 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| bclState The state of the Battery Current Limit process. | scalar | BclState | .1.3.6.1.4.1.1918.2.14.10.70.50.10 |
| bclLimit BCL maintains the battery current below this value, which is a percentage of the installed C10 Battery Capacity. | scalar | % Unsigned8 | .1.3.6.1.4.1.1918.2.14.10.70.50.30 |
| bclOffsetVoltage The bus voltage adjustment made by Battery Current Limit is applied to the Operating Voltage to produce the Target Voltage. Target Voltage is used as the input to the AVC function. | scalar | 0.01 V Float | .1.3.6.1.4.1.1918.2.14.10.70.50.40 |
| enableBatteryCurrentLimit Protects the batteries from excessive charge current. BCL varies the system voltage in order to maintain battery charge current below the BCL Limit value. | scalar | EnableState | .1.3.6.1.4.1.1918.2.14.10.70.50.5 |
| bclEngineRunLimit The Battery Current Limit setting when the Engine Run State is 'Running'. BCL maintains the battery current below this value when the Engine Run State is 'Running'. This limit is … | scalar | % Unsigned8 | .1.3.6.1.4.1.1918.2.14.10.70.50.50 |