aiLowNotes
RPS-SC300-MIB ·
.1.3.6.1.4.1.1918.2.14.10.90.10.30.1.240
Object
column
r/w
OctetString
User notes about this alarm. These notes appear in SNMP traps and can be viewed using DCTools or PowerManagerII.
Context
- MIB
- RPS-SC300-MIB
- OID
.1.3.6.1.4.1.1918.2.14.10.90.10.30.1.240- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- analogInputEntry
- Table
- analogInputTable
- Siblings
- 26
Syntax
OctetString
Values & Constraints
Object Constraints
range: 0-60
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| analogInputIndex Automatically generated index object. | column | Integer32 | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.1 |
| gain The scaling factor applied to the raw value read from the I/O board. | column | 0.01 Float | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.100 |
| offset The offset applied to the raw value read from the I/O board. | column | 0.01 Float | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.110 |
| hysteresis The amount of hysteresis applied to the input before an active alarm is deactivated. | column | 0.01 Float | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.130 |
| highSeverity The severity level associated with the alarm. Control alarms are not displayed, although any configured digital outputs are still activated. | column | AlarmSeverity | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.141 |
| highThreshold An analog input high alarm is activated if the scaled input is greater than or equal to this value. | column | 0.01 Float | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.150 |
| highDoMappingA Optional digital output activated while this alarm is active. | column | RelayMapping | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.160 |
| highDoMappingB Optional digital output activated while this alarm is active. | column | RelayMapping | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.170 |
| highTrapSend If set to true an SNMP trap is sent to every trap receiver with an appropriate trap level whenever this alarm changes state. | column | SendTrap | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.175 |
| lowSeverity The severity level associated with the alarm. Control alarms are not displayed, although any configured digital outputs are still activated. | column | AlarmSeverity | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.181 |
| lowThreshold An analog input low alarm is activated if the scaled input is lower than or equal to this value. | column | 0.01 Float | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.190 |
| aiHighState The state of the selected analog input high alarm. | column | AlarmActiveState | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.20 |
| lowDoMappingA Optional digital output activated while this alarm is active. | column | RelayMapping | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.200 |
| lowDoMappingB Optional digital output activated while this alarm is active. | column | RelayMapping | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.210 |
| lowTrapSend If set to true an SNMP trap is sent to every trap receiver with an appropriate trap level whenever this alarm changes state. | column | SendTrap | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.215 |
| aiGroup The group tag used by software to group related inputs and outputs for display purposes. | column | Unsigned8 | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.220 |
| aiHighNotes User notes about this alarm. These notes appear in SNMP traps and can be viewed using DCTools or PowerManagerII. | column | OctetString | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.230 |
| aiLowState The state of the selected analog input low alarm. | column | AlarmActiveState | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.30 |
| aiValue Analog input value. | column | 0.01 Float | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.40 |
| aiStatus Enable/disable this analog input channel. | column | EnableState | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.50 |
| aiName The name of this analog input channel as it will appear on management software such as DCTools or PowerManagerII. This name is not displayed on the controller. | column | OctetString | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.60 |
| aiFunction Selects how the value of this analog input is to be used by any control functions, if at all. | column | AiFunction | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.64 |
| aiFunctionIndex Select an index for the selected function. Only valid where function is Smart-Analog, Battery-Symmetry-Monitoring and Fan-Temperature. | column | Unsigned8 | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.66 |
| aiUnits Units of this analog input (after scaling). | column | MeasurementUnits | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.70 |
| aiIobNumber The I/O board number on which this analog input is located. | column | Unsigned8 | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.80 |
| inputNumber The input channel on the I/O board of this analog input. | column | Unsigned8 | .1.3.6.1.4.1.1918.2.14.10.90.10.30.1.90 |