ahDischargedFloatResetRate
RPS-SC300-MIB ·
.1.3.6.1.4.1.1918.2.14.10.70.27
Object
scalar
r/w
0.1 Float
Once the battery has returned to float the Ah discharged figure is adjust towards zero by this factor multiplied by Battery-State-Threshold. In Solar applications where the amount of time spent in float is small a large factor is appropriate.
Context
- MIB
- RPS-SC300-MIB
- OID
.1.3.6.1.4.1.1918.2.14.10.70.27- Type
- scalar
- Access
- readwrite
- Status
- current
- Units
- 0.1
- Parent
- controlFunctions
- Siblings
- 13
Syntax
0.1 Float
- Source
- Float
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| voltageControl | node | - | .1.3.6.1.4.1.1918.2.14.10.70.10 |
| temperatureCompensation | node | - | .1.3.6.1.4.1.1918.2.14.10.70.20 |
| resetAhDischarged This command resets controller battery state information (Amp hours discharged) and reverts all control process states to Inactive. | scalar | NoData | .1.3.6.1.4.1.1918.2.14.10.70.25 |
| equalize | node | - | .1.3.6.1.4.1.1918.2.14.10.70.30 |
| fastCharge | node | - | .1.3.6.1.4.1.1918.2.14.10.70.40 |
| controlState Indicates the state of control process, e.g. Equalize, Fast Charge or Normal. | scalar | ControlState | .1.3.6.1.4.1.1918.2.14.10.70.5 |
| batteryCurrentLimit | node | - | .1.3.6.1.4.1.1918.2.14.10.70.50 |
| batteryTest | node | - | .1.3.6.1.4.1.1918.2.14.10.70.70 |
| lvd | node | - | .1.3.6.1.4.1.1918.2.14.10.70.75 |
| generatorControl | node | - | .1.3.6.1.4.1.1918.2.14.10.70.80 |
| peakLoadReduction | node | - | .1.3.6.1.4.1.1918.2.14.10.70.85 |
| energyMeters | node | - | .1.3.6.1.4.1.1918.2.14.10.70.87 |
| fanController | node | - | .1.3.6.1.4.1.1918.2.14.10.70.88 |