unit3OutputType
RITTAL-CMC-TC-MIB ·
.1.3.6.1.4.1.2606.4.2.5.6.2.1.2
Object
column
mandatory
Enumeration
Type of output which is connected to sensor unit 3 to output[unit3OutputIndex] 1: no output connected 2: output failure 3: value overflow 4: output type 1, door locking TS8,Ergoform 5: output type 2, universal lock 1, lock with power 6: output type 3, universal lock 2, unlock with power 7: output type 4, fan relay 8: output type 5, fan controlled 9: output type 6, universal relay output 10: output type 7, room door lock 11: output type 8, power output 12: output type 9, door lock with Master key 13: output type 10, door lock FR(i) 14: setpoint (FCS, RTT) 15: setpoint temperature monitoring (RTT) 16: hysteresis of setpoint (RCT) 17: command for remote control of RCT 18: relay PSM, 1=On, 0=Off 19: high setpoint current monitoring PSM 20: low setpoint current monitoring PSM 21: setpoint temperature RTT 22: setpoint temperature monitoring RTT 23: power output 20A 24: door magnet (automatic door release) 30: control mode LCP 31: min fan speed (fan control) LCP 32: min delta T (fan control) LCP 33: max delta T (fan control) LCP 34: PID controller, KP, LCP 35: PID controller, KI, LCP 36 PID controller, KD, LCP 37 flowrate flowmeter, LCP 38: cw value of water (default: 4187) LCP 39: deltaT, LCP 40: control mode, LCP 42: setpoint high voltage PSM 43: setpoint low voltage PSM 44: setpoint high current PSM 45: setpoint low current PSM 46: command PSM
Context
- MIB
- RITTAL-CMC-TC-MIB
- OID
.1.3.6.1.4.1.2606.4.2.5.6.2.1.2- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- cmcTcUnit3OutputEntry
- Table
- cmcTcUnit3OutputTable
- Siblings
- 8
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | notAvail |
2 | failure |
3 | overflow |
4 | doorLock |
5 | univLock1 |
6 | univLock2 |
7 | fan |
8 | fanSpeedContr |
9 | universalOut |
10 | roomLock |
11 | powerOut |
12 | doorLockMaster |
13 | doorLockFRi |
14 | setpoint |
15 | setpointTimax |
16 | hysteresisRCT |
17 | commandRCT |
18 | relayPSM |
19 | setHighPSM |
20 | setLowPSM |
21 | setpointRTT |
22 | setTimaxRTT |
23 | powerOut1 |
24 | doorMagnet |
30 | controlModeLCP |
31 | minFanSpeedLCP |
32 | minDeltaTLCP |
33 | maxDeltaTLCP |
34 | kPLCP |
35 | kILCP |
36 | kDLCP |
37 | flowRateLCP |
38 | cwValueLCP |
39 | deltaTLCP |
40 | ctrModLCP |
42 | voltHighPSM |
43 | voltLowPSM |
44 | ampHighPSM |
45 | ampLowPSM |
46 | commandPSM |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| unit3OutputIndex mandatory Index for the list of output entries. Its value ranges
between 1 and the value of cmcTcUnit3NumberOfOutputs. | column | Integer32 | .1.3.6.1.4.1.2606.4.2.5.6.2.1.1 |
| unit3OutputText mandatory Descriptional text for each output (entry in the table) | column | OctetString | .1.3.6.1.4.1.2606.4.2.5.6.2.1.3 |
| unit3OutputStatus mandatory Actual status of the output | column | Enumeration | .1.3.6.1.4.1.2606.4.2.5.6.2.1.4 |
| unit3OutputValue mandatory Value for output | column | Integer32 | .1.3.6.1.4.1.2606.4.2.5.6.2.1.5 |
| unit3OutputSet mandatory Command for output | column | Enumeration | .1.3.6.1.4.1.2606.4.2.5.6.2.1.6 |
| unit3OutputConfig mandatory Configuration for output
1: disable remote control (e.g. keypad)
2: enable remote control | column | Enumeration | .1.3.6.1.4.1.2606.4.2.5.6.2.1.7 |
| unit3OutputDelay mandatory Unsigned Value for delay,
after this time the output will fall into the previous state | column | Integer32 | .1.3.6.1.4.1.2606.4.2.5.6.2.1.8 |
| unit3OutputTimeoutAction mandatory State for output if timeout (RS422) occurs | column | Enumeration | .1.3.6.1.4.1.2606.4.2.5.6.2.1.9 |