rbnSRSwitchoverEvent
RBN-SYS-RESOURCES-MIB ·
.1.3.6.1.4.1.2352.2.24.0.2
Object
notification
This notification identifies when a switchover occurs from one main processor module to a backup.
Context
- MIB
- RBN-SYS-RESOURCES-MIB
- OID
.1.3.6.1.4.1.2352.2.24.0.2- Type
- notification
- Status
- current
- Parent
- rbnSRMIBNotifications
- Siblings
- 13
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| rbnSRProcessEvent This notification is sent each time the agent is informed of
a process death/birth event. | notification | - | .1.3.6.1.4.1.2352.2.24.0.1 |
| rbnSseDiskVoltageFailureAlarm A rbnSseDiskVoltageFailureAlarm notification signifies that the
hard disk voltage has failed. | notification | - | .1.3.6.1.4.1.2352.2.24.0.10 |
| rbnSseDiskOverHeatAlarm A rbnSseDiskOverHeatAlarm notification signifies that the
hard disk overheating. | notification | - | .1.3.6.1.4.1.2352.2.24.0.11 |
| rbnSseDiskReadFailureAlarm A rbnSseDiskReadFailureAlarm notification signifies that the
hard disk read failure. | notification | - | .1.3.6.1.4.1.2352.2.24.0.12 |
| rbnIssuStateChange A notification reporting a change in ISSU state. The new
state is returned in the notification. | notification | - | .1.3.6.1.4.1.2352.2.24.0.13 |
| rbnChassisAlarm A rbnChassisAlarm notification signifies that
an alarm has been raised/cleared on the chassis. | notification | - | .1.3.6.1.4.1.2352.2.24.0.14 |
| rbnSRStorageFailedEvent This notification is sent when the value of
rbnSRStorageStatus for a device changes to 'failed'. | notification | - | .1.3.6.1.4.1.2352.2.24.0.3 |
| rbnSRPowerExceededEvent This notification identifies when a controller card
is inserted and results in more power being drawn
than recommended. | notification | - | .1.3.6.1.4.1.2352.2.24.0.4 |
| rbnSseDiskHealthDegradedAlarm A rbnSseDiskHealthDegradedAlarm notification signifies that the
hard disk health has degraded. | notification | - | .1.3.6.1.4.1.2352.2.24.0.5 |
| rbnSseDiskFailedAlarm A rbnSseDiskFailedAlarm notification signifies that the
hard disk has failed. | notification | - | .1.3.6.1.4.1.2352.2.24.0.6 |
| rbnSseDiskMissingAlarm A rbnSseDiskMissingAlarm notification signifies that the
hard disk is missing. | notification | - | .1.3.6.1.4.1.2352.2.24.0.7 |
| rbnSseDiskUnsupportedAlarm A rbnSseDiskUnsupportedAlarm notification signifies that the
hard disk is not supported. | notification | - | .1.3.6.1.4.1.2352.2.24.0.8 |
| rbnSseDiskOOSAlarm A rbnSseDiskOOSAlarm notification signifies that the
hard disk is out of service. | notification | - | .1.3.6.1.4.1.2352.2.24.0.9 |