RBN-SYS-RESOURCES-MIB
The management information definitions for the
system resources management of a Redback network
device. This MIB is viewable under all contexts.
rbnSysResourcesMib
1.3.6.1.4.1.2352.2.24
Imported Objects
| IANA-ITU-ALARM-TC-MIB | IANAItuEventType IANAItuProbableCause |
| ITU-ALARM-TC-MIB | ItuPerceivedSeverity |
| RBN-SMI | rbnMgmt |
| RBN-TC | RbnKBytes RbnPercentage RbnSlot |
| SNMP-FRAMEWORK-MIB | SnmpAdminString |
| SNMPv2-CONF | MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | Counter32 Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE TimeTicks Unsigned32 |
| SNMPv2-TC | DateAndTime TruthValue |
Objects (56)
|
|
.1.3.6.1.4.1.2352.2.24 |
|
|
|
.1.3.6.1.4.1.2352.2.24.0 |
|
|
|
.1.3.6.1.4.1.2352.2.24.1 |
|
|
|
.1.3.6.1.4.1.2352.2.24.1.1 |
|
|
|
SNMPv2-SMITimeTicks | .1.3.6.1.4.1.2352.2.24.1.1.1 |
|
|
Enumeration | .1.3.6.1.4.1.2352.2.24.1.1.2 |
|
|
.1.3.6.1.4.1.2352.2.24.1.1.3 |
|
|
|
rbnSRProcessNotifyProcName | .1.3.6.1.4.1.2352.2.24.1.1.3.1 |
|
|
OctetString | .1.3.6.1.4.1.2352.2.24.1.1.3.1.1 |
|
|
Unsigned32 | .1.3.6.1.4.1.2352.2.24.1.1.3.1.2 |
|
|
Enumeration | .1.3.6.1.4.1.2352.2.24.1.1.3.1.3 |
|
|
Enumeration | .1.3.6.1.4.1.2352.2.24.1.1.3.1.4 |
|
|
Unsigned32 | .1.3.6.1.4.1.2352.2.24.1.1.3.1.5 |
|
|
SNMPv2-SMITimeTicks | .1.3.6.1.4.1.2352.2.24.1.1.3.1.6 |
|
|
.1.3.6.1.4.1.2352.2.24.1.10 |
|
|
|
Enumeration | .1.3.6.1.4.1.2352.2.24.1.10.1 |
|
|
.1.3.6.1.4.1.2352.2.24.1.11 |
|
|
|
.1.3.6.1.4.1.2352.2.24.1.11.1 |
|
|
|
IANA-ITU-ALARM-TC-MIBIANAItuEventType | .1.3.6.1.4.1.2352.2.24.1.11.2 |
|
|
SNMPv2-TCDateAndTime | .1.3.6.1.4.1.2352.2.24.1.11.3 |
|
|
OctetString | .1.3.6.1.4.1.2352.2.24.1.11.4 |
|
|
IANA-ITU-ALARM-TC-MIBIANAItuProbableCause | .1.3.6.1.4.1.2352.2.24.1.11.5 |
|
|
ITU-ALARM-TC-MIBItuPerceivedSeverity | .1.3.6.1.4.1.2352.2.24.1.11.6 |
|
|
.1.3.6.1.4.1.2352.2.24.1.2 |
|
|
|
.1.3.6.1.4.1.2352.2.24.1.2.1 |
|
|
|
rbnSRStorageIndex | .1.3.6.1.4.1.2352.2.24.1.2.1.1 |
|
|
Integer32 | .1.3.6.1.4.1.2352.2.24.1.2.1.1.1 |
|
|
SNMPv2-SMICounter32 | .1.3.6.1.4.1.2352.2.24.1.2.1.1.10 |
|
|
OctetString | .1.3.6.1.4.1.2352.2.24.1.2.1.1.2 |
|
|
Enumeration | .1.3.6.1.4.1.2352.2.24.1.2.1.1.3 |
|
|
SNMPv2-TCTruthValue | .1.3.6.1.4.1.2352.2.24.1.2.1.1.4 |
|
|
KBytesRBN-TCRbnKBytes | .1.3.6.1.4.1.2352.2.24.1.2.1.1.5 |
|
|
RBN-TCRbnPercentage | .1.3.6.1.4.1.2352.2.24.1.2.1.1.6 |
|
|
RBN-TCRbnSlot | .1.3.6.1.4.1.2352.2.24.1.2.1.1.7 |
|
|
SNMPv2-SMITimeTicks | .1.3.6.1.4.1.2352.2.24.1.2.1.1.8 |
|
|
Enumeration | .1.3.6.1.4.1.2352.2.24.1.2.1.1.9 |
|
|
.1.3.6.1.4.1.2352.2.24.1.2.2 |
|
|
|
rbnSseDiskSlotrbnSseDiskNum | .1.3.6.1.4.1.2352.2.24.1.2.2.1 |
|
|
RBN-TCRbnSlot | .1.3.6.1.4.1.2352.2.24.1.2.2.1.1 |
|
|
Unsigned32 | .1.3.6.1.4.1.2352.2.24.1.2.2.1.2 |
|
|
Enumeration | .1.3.6.1.4.1.2352.2.24.1.2.2.1.3 |
|
|
GBytesUnsigned32 | .1.3.6.1.4.1.2352.2.24.1.2.2.1.4 |
|
|
GBytesUnsigned32 | .1.3.6.1.4.1.2352.2.24.1.2.2.1.5 |
|
|
.1.3.6.1.4.1.2352.2.24.1.3 |
|
|
|
SNMPv2-SMITimeTicks | .1.3.6.1.4.1.2352.2.24.1.3.1 |
|
|
SNMPv2-TCDateAndTime | .1.3.6.1.4.1.2352.2.24.1.3.2 |
|
|
.1.3.6.1.4.1.2352.2.24.1.4 |
|
|
|
Enumeration | .1.3.6.1.4.1.2352.2.24.1.4.1 |
|
|
SNMPv2-TCDateAndTime | .1.3.6.1.4.1.2352.2.24.1.5 |
|
|
ITU-ALARM-TC-MIBItuPerceivedSeverity | .1.3.6.1.4.1.2352.2.24.1.6 |
|
|
IANA-ITU-ALARM-TC-MIBIANAItuProbableCause | .1.3.6.1.4.1.2352.2.24.1.7 |
|
|
IANA-ITU-ALARM-TC-MIBIANAItuEventType | .1.3.6.1.4.1.2352.2.24.1.8 |
|
|
OctetString | .1.3.6.1.4.1.2352.2.24.1.9 |
|
|
.1.3.6.1.4.1.2352.2.24.2 |
|
|
|
.1.3.6.1.4.1.2352.2.24.2.1 |
|
|
|
.1.3.6.1.4.1.2352.2.24.2.2 |
Notifications / Traps (14)
| Name | OID | Description |
|---|---|---|
|
|
.1.3.6.1.4.1.2352.2.24.0.1 |
This notification is sent each time the agent is informed of a process death/birth event. |
|
|
.1.3.6.1.4.1.2352.2.24.0.10 |
A rbnSseDiskVoltageFailureAlarm notification signifies that the hard disk voltage has failed. |
|
|
.1.3.6.1.4.1.2352.2.24.0.11 |
A rbnSseDiskOverHeatAlarm notification signifies that the hard disk overheating. |
|
|
.1.3.6.1.4.1.2352.2.24.0.12 |
A rbnSseDiskReadFailureAlarm notification signifies that the hard disk read failure. |
|
|
.1.3.6.1.4.1.2352.2.24.0.13 |
A notification reporting a change in ISSU state. The new state is returned in the notification. |
|
|
.1.3.6.1.4.1.2352.2.24.0.14 |
A rbnChassisAlarm notification signifies that an alarm has been raised/cleared on the chassis. |
|
|
.1.3.6.1.4.1.2352.2.24.0.2 |
This notification identifies when a switchover occurs from one main processor module to a backup. |
|
|
.1.3.6.1.4.1.2352.2.24.0.3 |
This notification is sent when the value of rbnSRStorageStatus for a device changes to 'failed'. |
|
|
.1.3.6.1.4.1.2352.2.24.0.4 |
This notification identifies when a controller card is inserted and results in more power being drawn than recommended. |
|
|
.1.3.6.1.4.1.2352.2.24.0.5 |
A rbnSseDiskHealthDegradedAlarm notification signifies that the hard disk health has degraded. |
|
|
.1.3.6.1.4.1.2352.2.24.0.6 |
A rbnSseDiskFailedAlarm notification signifies that the hard disk has failed. |
|
|
.1.3.6.1.4.1.2352.2.24.0.7 |
A rbnSseDiskMissingAlarm notification signifies that the hard disk is missing. |
|
|
.1.3.6.1.4.1.2352.2.24.0.8 |
A rbnSseDiskUnsupportedAlarm notification signifies that the hard disk is not supported. |
|
|
.1.3.6.1.4.1.2352.2.24.0.9 |
A rbnSseDiskOOSAlarm notification signifies that the hard disk is out of service. |