rcErpsHoldOffTime

RAISECOM-ERPS-MIB · .1.3.6.1.4.1.8886.6.1.53.1.2.1.15

Object

column r/w Unsigned32
When a new defect or more severe defect occurs (new SF), this event will not be 
reported immediately to protection switching if the provisioned holdoff timer 
value is non-zero. Instead, the holdoff timer will be started. When the holdoff 
timer expires, whether a defect still exists on the trail that started the timer
will be checked. If one does exist, that defect will be reported to protection 
switching. Each protection group should have a provisionable holdoff timer. The 
suggested range of the holdoff timer is 0 to 10 seconds in steps of 100 ms with 
an accuracy of 5 ms.

Context

MIB
RAISECOM-ERPS-MIB
OID
.1.3.6.1.4.1.8886.6.1.53.1.2.1.15
Type
column
Access
readwrite
Status
current
Parent
rcErpsCfgEntry
Table
rcErpsCfgTable
Siblings
11

Syntax

Unsigned32

Values & Constraints

Object Constraints
range: 0-100

Related Objects

Sibling Objects