rcErpsGuardTime

RAISECOM-ERPS-MIB · .1.3.6.1.4.1.8886.6.1.53.1.2.1.12

Object

column r/w Unsigned32
The guard timer is used  to prevent Ethernet ring nodes from acting upon 
outdated R-APS messages and prevents the possibility of forming a closed loop.
The period of the guard timer may be configured by the operator in 10 ms steps 
between 10 ms and 2 seconds, with a default value of 500 ms.

Context

MIB
RAISECOM-ERPS-MIB
OID
.1.3.6.1.4.1.8886.6.1.53.1.2.1.12
Type
column
Access
readwrite
Status
current
Parent
rcErpsCfgEntry
Table
rcErpsCfgTable
Siblings
11

Syntax

Unsigned32

Values & Constraints

Object Constraints
range: 20-2000

Related Objects