snarSaveChanges

RAD-MIB · .1.3.6.1.4.1.164.5.1.1.5

Object

scalar r/w Enumeration
N/A to SNAR, only for devices. When changes are made to any 
configuration parameters (SNA, NVA or others) it should be 
stored in the device's NVRAM and then the device is restarted.
Using this variable the manager can:
2 - Just save into NVRAM all configuration changes
3 - Save into NVRAM the configuration changes and restart the
    Device, to reflect the changes.
4 - Undo all  changes  since  last reset or
    save, (without resetting the device).
    Load the original configuration from the NVRAM.

Context

MIB
RAD-MIB
OID
.1.3.6.1.4.1.164.5.1.1.5
Type
scalar
Access
readwrite
Status
current
Parent
snarState
Siblings
3

Syntax

Enumeration

Values & Constraints

No enumerated values or constraints recorded.

Related Objects