radBridgeCODAnswerConnectCondition

RAD-MIB · .1.3.6.1.4.1.164.4.1.4.4.1.5

Object

column r/w Enumeration
CODCondAnswerConnect allows the user to specify 
the condition under which the link is connected.
The options are: 
   onPowerOn           - On power on.
   whenAnyStationOnLan - When any station on lan.
   onTraffic           - On traffic. The user can specify the 
                         condition/s for connection.
                         The connection will be defined in
                         CODSpecificOnTrafficConditionOID .
   onManualConnect     - depends on radBridgeCODManualConnect 
                         OBJECT-TYPE .

Context

MIB
RAD-MIB
OID
.1.3.6.1.4.1.164.4.1.4.4.1.5
Type
column
Access
readwrite
Status
current
Parent
radBridgeCODCondEntry
Table
radBridgeCODCondTable
Siblings
6

Syntax

Enumeration

Values & Constraints

Enumerated Values
1macAddress
2netAddress
3ipRange
4appleAddress

Related Objects