prtT1E1LineType
RAD-MIB ·
.1.3.6.1.4.1.164.3.3.3.2.2.1.4
Object
column
r/w
Enumeration
This variable indicates the variety of T1/E1
Line implementing this circuit. The type of
circuit affects the number of bits per second
that the circuit can reasonably carry, as well
as the interpretation of the usage and error
statistics. The values, in sequence, describe:
TITLE: SPECIFICATION:
esf Extended SuperFrame DS1
d4 AT&T D4 format DS1 - SF
e1 CCITT Recommendation G.704
(Table 4a) - G732N
e1Crc CCITT Recommendation G.704
(Table 4b) - G732N with CRC
e1MF G.704 (Table 4a) with TS16
multiframing enabled - G732S
e1CrcMF G.704 (Table 4b) with TS16
multiframing enabled - G732S with CRC
unframed
T1 - applicable values: (1),(2),(3),(8)
E1 - applicable values: (1),(4),(5),(6),(7),(8)
Context
- MIB
- RAD-MIB
- OID
.1.3.6.1.4.1.164.3.3.3.2.2.1.4- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- prtT1E1CnfgEntry
- Table
- prtT1E1CnfgTable
- Siblings
- 33
Syntax
Enumeration
Values & Constraints
Enumerated Values
2 | off |
3 | on |
255 | notApplicable |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| prtT1E1CnfgIdx This attribute indicates the Idx of the Config being accessed.
Idx of 255 relates to the Temporary (Scratch) Config. | column | Integer32 | .1.3.6.1.4.1.164.3.3.3.2.2.1.1 |
| prtT1E1CGA This object selects the method used to signal the CGA state
to the other end, through the main/sub link.
'none' - non-transparent mode. When one of the links
(main/su… | column | Enumeration | .1.3.6.1.4.1.164.3.3.3.2.2.1.10 |
| prtT1E1IdleCode This object selects the code transmitted to fill idle
(unused) time slots in the main link frame.
Valid range: (0 - FF HEX) . | column | OctetString | .1.3.6.1.4.1.164.3.3.3.2.2.1.11 |
| prtT1E1OosSignal 'idle' = '0' = on-hook, idle state
'busy' = '1' = off-hook, busy state
'forcedIdle' = SP = both A and B signaling bits are forced
to '0' during out-of-service perio… | column | Enumeration | .1.3.6.1.4.1.164.3.3.3.2.2.1.12 |
| prtT1E1VoiceOos Voice Out-Of-Service code. Valid range: (0 - FF HEX).
For agents that do not support this feature, the value will
always be 0. | column | OctetString | .1.3.6.1.4.1.164.3.3.3.2.2.1.13 |
| prtT1E1DataOos Data Out-Of-Service code. Valid range: (0 - FF HEX).
For agents that do not support this feature, the value will
always be 0. | column | OctetString | .1.3.6.1.4.1.164.3.3.3.2.2.1.14 |
| prtT1E1LineLengthMask This attribute is the line length mask parameter used only
for T1/DSU interfaces.
len400p533ft=length range: 400ft to 533ft
'fcc68' - provides compliance with the FCC 68.308 Opt… | column | Enumeration | .1.3.6.1.4.1.164.3.3.3.2.2.1.15 |
| prtT1E1TxGainMask This attribute is the tx gain mask parameter (dB), used
only for T1/CSU interfaces. | column | Enumeration | .1.3.6.1.4.1.164.3.3.3.2.2.1.16 |
| prtT1E1InbandMng A unique number to identify an Inband management over the
link.
internal - supported by KM-2100 only. It means that the management is internal
to the frame. It takes p… | column | Enumeration | .1.3.6.1.4.1.164.3.3.3.2.2.1.17 |
| prtT1E1InbandMngRate A unique number to identify the rate of the Inband management.
It is required only for E1 links and is applicable only when
prtExT1E1InbandMng selected is FdlOrTs0 or dedicatedTs. | column | Enumeration | .1.3.6.1.4.1.164.3.3.3.2.2.1.18 |
| prtT1E1DedicatedTs The value is differently determined for different products.
There are two methods:
1) A unique number to identify Dedicated TS of the T1/E1 port.
It is applicabl… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.164.3.3.3.2.2.1.19 |
| prtT1E1PrtIdx This attribute indicates a unique port number.
The same numbering as for prtGenPrtIdx.
The valid port number depends on the IO slot no., the
installed card type and the p… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.164.3.3.3.2.2.1.2 |
| prtT1E1InbandMngRoutProt Inband Mng Routing Protocol of the port.
When prtT1E1InbandMng is 'dedicatedPpp'-'proprietary' and
'rip2' are applicable.
For other values … | column | Enumeration | .1.3.6.1.4.1.164.3.3.3.2.2.1.20 |
| prtT1E1LinkMode regular - TSs are connected by user via TS Assignment only
transparent - when a port with this Link Mode is connected to an
internal T1/E1 port of a T3/E3 card, TS0… | column | Enumeration | .1.3.6.1.4.1.164.3.3.3.2.2.1.21 |
| prtT1E1Multiplier The data rate of each TS. The multiplier values
can be 56 kbps or 64 kbps. For T1 only. | column | Enumeration | .1.3.6.1.4.1.164.3.3.3.2.2.1.22 |
| prtT1E1RxGain This attribute is the rx volume (dB). | column | Enumeration | .1.3.6.1.4.1.164.3.3.3.2.2.1.23 |
| prtT1E1RAI Remote Alarm Signal | column | Enumeration | .1.3.6.1.4.1.164.3.3.3.2.2.1.24 |
| prtT1E1LineMode Interface type of the port.
For T1 - csu, dsu are the valid values
For E1 - dsu, ltu are the valid values | column | Enumeration | .1.3.6.1.4.1.164.3.3.3.2.2.1.25 |
| prtT1E1TS0SaBits This object is applicable only for E1 ports. For T1, string size will be 0.
For E1, it enables user to select the use of TS0 Sa Bits 4..8, by 3 octets:
The order (in hexa displa… | column | OctetString | .1.3.6.1.4.1.164.3.3.3.2.2.1.26 |
| prtT1E1ConnectedTS This parameter indicates if there is any connected TS for this interface. | column | Enumeration | .1.3.6.1.4.1.164.3.3.3.2.2.1.27 |
| prtT1E1Ts0SaBit This parameter indicates whether to send TS 0, or not.
noMng= TS 0 is looped, therefore not sent.
mng= TS 0 isn't looped, therefore it is sent. | column | Enumeration | .1.3.6.1.4.1.164.3.3.3.2.2.1.28 |
| prtT1E1SameFeCnfg This parameter indicates whether the same E1 configuration
parameters and TS assignment are set both to the local
and remote device.
Read-Write access is applicable only in G732N… | column | Enumeration | .1.3.6.1.4.1.164.3.3.3.2.2.1.29 |
| prtT1E1Slt This attribute indicates a unique number to identify the slot where
the card is inserted in.
When the unit is stand-alone, this object is not applicable
and 255 will be used. | column | Enumeration | .1.3.6.1.4.1.164.3.3.3.2.2.1.3 |
| prtT1E1RemCrc4 This object indicates whether the E1 of the Remote device
connected to this E1 port, will have CRC-4 or not. | column | Enumeration | .1.3.6.1.4.1.164.3.3.3.2.2.1.30 |
| prtT1E1MaxTSs This object is applicable only for DXC D4T1, D4E1, D8T1, D8E1
external ports and D8GSL internal E1 ports.
It is relevant only when sysCIntTsAllocMode=static(2).
255=not appli… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.164.3.3.3.2.2.1.31 |
| prtT1E1EocTsConfig This object indicates whether the use of EOC for TS Configuration
is enabled or not. | column | Enumeration | .1.3.6.1.4.1.164.3.3.3.2.2.1.32 |
| prtT1E1Role This object indicates whether this port behaves as SUB or Main link. | column | Enumeration | .1.3.6.1.4.1.164.3.3.3.2.2.1.33 |
| prtT1E1PppEchoFailDetection This object indicates whether the PPP Echo is taken into account
for its Fail Detection.
This object is relevant when Inband Mng between devices is Dedicated TS PPP.
Default=Dis… | column | Enumeration | .1.3.6.1.4.1.164.3.3.3.2.2.1.34 |
| prtT1E1LineCode This variable describes the variety of Zero
Code Suppression used on the link, which in
turn affects a number of its characteristics.
jbzs=b7zs refers the Ja… | column | Enumeration | .1.3.6.1.4.1.164.3.3.3.2.2.1.5 |
| prtT1E1SignalMode 'none' indicates that no bits are reserved for
signaling on this channel.
'robbedBit' indicates that T1 Robbed Bit Signaling is in use.
'bitOriented'… | column | Enumeration | .1.3.6.1.4.1.164.3.3.3.2.2.1.6 |
| prtT1E1Fdl This bitmap describes the use of the facili-
ties data link, and is the sum of the capabili-
ties:
'other' indicates that a protocol other than
one following i… | column | Enumeration | .1.3.6.1.4.1.164.3.3.3.2.2.1.7 |
| prtT1E1FdlMode Fdl Mode of the T1 selected port.
notApplicable - will be used for an E1 port. | column | Enumeration | .1.3.6.1.4.1.164.3.3.3.2.2.1.8 |
| prtT1E1Sync This object enables returning to normal operation, after
the end of a main/sub link red alarm event, in reduced time.
'tr62411' - complies with AT&T TR-62411 (after 10 seconds… | column | Enumeration | .1.3.6.1.4.1.164.3.3.3.2.2.1.9 |