prtMonitoredPort

RAD-MIB · .1.3.6.1.4.1.164.3.3.3.1.6.1.5

Object

column r/w SNMPv2-SMIInteger32
This object indicates the MONITORED Port Index that the Monitoring
port monitors.
	   For DXC:
  The valid port number depends on the IO slot no.,  the 
  installed card type and the port type: external, internal.
  * The external ports will according to the convention (for DXC):
    - first two digits will be: (IO slot number+10)
    - last one/two digits will be the port number within the 
      card, in odd numbers:
      port1 = 1
      port2 = 3
      port3 = 5 
      etc...
    Example: port2 of IO slot 11 will be: 213 .
  * The internal ports will be according to the convention (for DXC):
    - first two digits will be: (IO slot number+10)
    - last one/two digits will be the port number within the 
      card, in even numbers:
      port1 = 2
      port2 = 4
      port3 = 6 
      etc...
    Example: port2 of IO slot 11 will be: 214 .
  * 100 - no port monitored
For Optimux-T3:
	     The valid channels are:
  0 =  no Ch monitored
  1..21 or 1..28 (=CH1..CH21 or CH1..CH28) according to product's 
  configuration.

Context

MIB
RAD-MIB
OID
.1.3.6.1.4.1.164.3.3.3.1.6.1.5
Type
column
Access
readwrite
Status
current
Parent
prtMonEntry
Table
prtMonTable
Siblings
5

Syntax

SNMPv2-SMIInteger32
Source
SNMPv2-SMIInteger32
Base type
Integer32

Values & Constraints

Enumerated Values
1notApplicable
2off
3on
Type Constraints
range: -2147483648..2147483647

Related Objects

Sibling Objects