prtHSBertPrtIdx
RAD-MIB ·
.1.3.6.1.4.1.164.3.3.3.3.2.1.1
Object
column
SNMPv2-SMIInteger32
This attribute indicates a unique number to identify a port.
The valid port number depends on the IO slot no., the
installed card type and the port type: outside, inside,
SP.
* The inside ports will be the HS cards ports. The
convention used will be (for DXC):
- first two digits will be: (IO slot number+10)
- last one/two digits will be the port number within the
card, in even numbers:
port1 = 2
port2 = 4
port3 = 6
etc...
Example: port2 of IO slot 11 will be: 214 .
Context
- MIB
- RAD-MIB
- OID
.1.3.6.1.4.1.164.3.3.3.3.2.1.1- Type
- column
- Access
- readonly
- Status
- current
- Parent
- prtHSBertEntry
- Table
- prtHSBertTable
- Siblings
- 3
Syntax
SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| prtHSBertSlt This attribute indicates a unique number to identify the slot where
the card is inserted in.
When the unit is stand-alone, this object is not applicable
and 255 will be used. | column | Enumeration | .1.3.6.1.4.1.164.3.3.3.3.2.1.2 |
| prtHSBertCountClr Setting this object (to on) initiate bert counter clear
operation.
Valid only when bert test is active on the specific port.
(Every time a new bert test starts, the counter is
a… | column | Enumeration | .1.3.6.1.4.1.164.3.3.3.3.2.1.3 |
| prtHSBertTestResult This object indicates the number of Bit Error Rate indicated
during the BERT test.
Active only when bert test is running on the selected port. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.164.3.3.3.3.2.1.4 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|
| prtICnfgIdx This attribute indicates the Idx of the Config being accessed.
Idx of 255 relates to the Temporary (Scratch) Config. | column | Integer32 | .1.3.6.1.4.1.164.3.3.3.6.1.1.1 |
| prtIIdx This attribute indicates a unique number to identify a port.
The valid port number depends on the IO slot no., the
installed card type and the port type: outside, inside,
SP.