prtExPhPlModemCallDelay
RAD-MIB ·
.1.3.6.1.4.1.164.3.2.3.2.3.3.1.8
Object
Time in Seconds that the device will wait before dialing to the remote
device.
This feature is mostly used when there is a backup modem to the
main link and the main link is down. In this case it is important to prevent
the 2 devices from dialing through the backup modems to each other at the same time.
It is advised to configure one side with a small call delay and the other side
with a large call delay.
Legal Values are:
0 - 30, 60, 120, 180, 240, 300, 600, 900, 1200, 1500, 1800 .
65535 sec. means that this parameter is not applicable.
Default: 0 sec
Context
- MIB
- RAD-MIB
- OID
.1.3.6.1.4.1.164.3.2.3.2.3.3.1.8- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- prtExPhPlModemEntry
- Table
- prtExPhPlModemTable
- Siblings
- 7
Syntax
SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Enumerated Values
1 | notApplicable |
2 | loopStart |
3 | groundStart |
4 | winkStart |
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| prtExPhPlModemCnfgIdx This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. | column | Integer32 | .1.3.6.1.4.1.164.3.2.3.2.3.3.1.1 |
| prtExPhPlModemSltIdx This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid | column | Enumeration | .1.3.6.1.4.1.164.3.2.3.2.3.3.1.2 |
| prtExPhPlModemPrtIdx This attribute indicates a unique port number.
In case of PH.1 card, only exPrt(1) is valid. | column | Enumeration | .1.3.6.1.4.1.164.3.2.3.2.3.3.1.3 |
| prtExPhPlModemStatus This object indicates whether a Dial Up Modem is enabled on this port.
Default: disable
For Vmux devices this object shows whether there is Modem Relay support. | column | Enumeration | .1.3.6.1.4.1.164.3.2.3.2.3.3.1.4 |
| prtExPhPlModemActivate This object indicates whether the Dial Up Modem is activated when
the first frame is received or it is always activated.
Default: onFirstFrame | column | Enumeration | .1.3.6.1.4.1.164.3.2.3.2.3.3.1.5 |
| prtExPhPlModemMaxIdleTime Max Time allowed in Seconds without any traffic before the line
is disconnected.
Legal Values are: 1 sec, 2 sec .. 5 sec, 10 sec, 20 sec..
1 min, 2 min .. 10 min, 1… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.164.3.2.3.2.3.3.1.6 |
| prtExPhPlModemTimeBtwnCalls Minimum Time in Seconds which is required after a call was
disconnected. In this time no other call will be initiated
from this Modem port even if there were frames transmitted
to… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.164.3.2.3.2.3.3.1.7 |