pktSwchSysDtrPollPeriodA

RAD-MIB · .1.3.6.1.4.1.164.8.1.1.2.12

Object

scalar Integer32
Polling interval for DTR signal, in miliseconds. DTR signal 
may be used as trigger	for opening and closing calls.
The value is in steps of 50 msec; if user sets it differently, it is
rounded to the nearest 50 msec multiple (e.g 380 will be rounded to 400).
Default value: 3000 msec.

Context

MIB
RAD-MIB
OID
.1.3.6.1.4.1.164.8.1.1.2.12
Type
scalar
Access
readonly
Status
current
Parent
pktSwchSysAParam
Siblings
11

Syntax

Integer32

Values & Constraints

Object Constraints
range: 0-255