linkSelectorRevert
RAD-MIB ·
.1.3.6.1.4.1.164.3.2.3.2.17.2.1.6
Object
column
r/w
Enumeration
If the link selector is in mode backup: auto(2)=return automatically to Main link when it is OK. manual(3)=stays connected to backup link.
Context
- MIB
- RAD-MIB
- OID
.1.3.6.1.4.1.164.3.2.3.2.17.2.1.6- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- linkSelectorCnfgEntry
- Table
- linkSelectorCnfgTable
- Siblings
- 6
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | exPrt1 |
2 | exPrt2 |
3 | exPrt3 |
4 | exPrt4 |
5 | exPrt5 |
6 | exPrt6 |
7 | exPrt7 |
8 | exPrt8 |
9 | exPrt9 |
10 | exPrt10 |
11 | exPrt11 |
12 | exPrt12 |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| linkSelectorCnfgIdx This attribute indicates the Idx of
the Cnfg (1..100) being accessed.
Idx 255 relates to the TmpCnfg. | column | Integer32 | .1.3.6.1.4.1.164.3.2.3.2.17.2.1.1 |
| linkSelectorSltIdx Slot Index | column | Enumeration | .1.3.6.1.4.1.164.3.2.3.2.17.2.1.2 |
| linkSelectorPrtIdx This attribute indicates a unique port number.
This port number should be internal port number:
higher or equal to linkSeL1(201). | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.164.3.2.3.2.17.2.1.3 |
| linkSelectorMaxIdleTime Move to higher prioritized connected link
after this period of seconds of silence on the current link.
0=move immediately to higher prioritized connected link.
UNIT is seconds. | column | Integer32 | .1.3.6.1.4.1.164.3.2.3.2.17.2.1.4 |
| linkSelectorMode If the link selector is in mode:
backup(2)=then the link with the lower priority will be
used in case of failure of the higher priority link,
bod(3)=bandwidth on demand … | column | Enumeration | .1.3.6.1.4.1.164.3.2.3.2.17.2.1.5 |
| linkSelectorMinBUSession Minimum duration of a backup session before
returning to Main Link. Relevant in Backup Mode and
when Revert is auto(2). Value 255 is for NEVER which
means never return to Main Li… | column | Integer32 | .1.3.6.1.4.1.164.3.2.3.2.17.2.1.7 |