etRptrMonitorTransmitCollisions

RAD-MIB · .1.3.6.1.4.1.164.9.1.1.9

Object

column SNMPv2-SMICounter32
This counter is incremented every time the
repeater state machine enters the TRANSMIT
COLLISION state from any state other than ONE PORT
LEFT (Ref: Fig 9-2, IEEE 802.3 Std).
              
The approximate minimum time for rollover of this
counter is 16 hours.

Context

MIB
RAD-MIB
OID
.1.3.6.1.4.1.164.9.1.1.9
Type
column
Access
readonly
Status
current
Parent
etRptrEntry
Table
etRptrTable
Siblings
8

Syntax

SNMPv2-SMICounter32
Source
SNMPv2-SMICounter32
Base type
Unsigned32

Values & Constraints

Object Constraints
range: 0-65535
Type Constraints
range: 0..4294967295

Related Objects

Sibling Objects