agnListDecodingSeverity
RAD-MIB ·
.1.3.6.1.4.1.164.3.1.2.7.1.1.5
Object
column
r/w
Enumeration
This object is applicable only for agnListDecodingType=alr.
It enables the user to select a severity for each alarm.
The severity is set per alarm code (same for all slots/ports
using this code).
event - can be set only for an alarm that is defined by
default as 'event'.
User can change the severity of the alarms defined by
default as minor or major.
The severity of an event may be set to another severity,
but the change will actually happen only if the event
threshold is active and passed the Set/ON condition.
An event alarm that passed the threshold and changed its
severity, will return automatically to event severity when
meeting its Reset/OFF condition.
Context
- MIB
- RAD-MIB
- OID
.1.3.6.1.4.1.164.3.1.2.7.1.1.5- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- agnListDecodingEntry
- Table
- agnListDecodingTable
- Siblings
- 6
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | active |
255 | temporary |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| agnListDecodingType The type of list the decoding data refers to.
alr - Alarms list
sanity - Sanity Check Error list.
counter - Counter type of ifPerfCounterType | column | Enumeration | .1.3.6.1.4.1.164.3.1.2.7.1.1.1 |
| agnListDecodingCode The specific code for which decoding is needed. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.164.3.1.2.7.1.1.2 |
| agnListDecodingDescription The description fitting the specific code and type of list
required. | column | OctetString | .1.3.6.1.4.1.164.3.1.2.7.1.1.3 |
| agnListDecodingDefState This object is applicable only for agnListDecodingType=alr.
It reports the default state/severity of each alarm.
User can change the severity of the alarms defined by
this defaul… | column | Enumeration | .1.3.6.1.4.1.164.3.1.2.7.1.1.4 |
| agnListDecodingAcmRelaySlt This object indicates the ACM slot, desired for outbound relay
(report) for the selected alarm.
In the ?004 Unit the entries io6(10)..io12(16) are not valid.
none - when agnLi… | column | Enumeration | .1.3.6.1.4.1.164.3.1.2.7.1.1.6 |
| agnListDecodingAcmRelayPrt This object indicates the ACM port within the slot, desired for outbound relay
(report) for the selected alarm.
notApplicable - when agnListDecodingType=sanity OR when
… | column | Enumeration | .1.3.6.1.4.1.164.3.1.2.7.1.1.7 |