agnCnfgAlrReportType
RAD-MIB ·
.1.3.6.1.4.1.164.3.1.2.2.8.3.1.1
Object
column
Enumeration
The alarm report type.
trap - traps will be sent only for alarms having the
selected On/Off severity or higher.
buffer - only alarms having the selected On/Off severity and
higher, will be reported to the buffer.
relay - relay contact will be activated only for alarms
having the selected On severity or higher.
For products having 2 relays, this is the R1 Relay.
alrLedOn/alrLedBlink - user should select a higher severity
(ReportOn) for alrLedBlink than for alrLedOn
(Blinking Led means a more severe alarm than steady
ON Led).
alrLedOn - MTCL-1 Alarm Led will be ON only when
agnSAlrStatusAll equals the selected severity or
higher, but lower severity than that selected for
'alrLedBlink'.
For products having 2 LEDs, this is the Minor LED.
alrLedBlink - MTCL-1 Alarm Led will Blink only when
agnSAlrStatusAll equals the selected severity or
higher.
For products having 2 LEDs, this is the Major LED.
relay2 - relay 2 contact will be activated only for alarms
having the selected On severity or higher.
This is the R2 Relay.
Context
- MIB
- RAD-MIB
- OID
.1.3.6.1.4.1.164.3.1.2.2.8.3.1.1- Type
- column
- Access
- readonly
- Status
- current
- Parent
- agnCnfgAlrReportEntry
- Table
- agnCnfgAlrReportTable
- Siblings
- 2
Syntax
Enumeration
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| agnCnfgAlrStartReportOn This object specifies the severity from which alarms will
be reported. Alarms having this severity or higher, will be
reported.
This object specifies the report severity only for… | column | Enumeration | .1.3.6.1.4.1.164.3.1.2.2.8.3.1.2 |
| agnCnfgAlrStartReportOff This object specifies the severity from which alarms will
be reported. Alarms having this severity or higher, will be
reported.
This object specifies the report severity only for… | column | Enumeration | .1.3.6.1.4.1.164.3.1.2.2.8.3.1.3 |