xPDUSystemOutputTableSize
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.15.3.4.13
Object
scalar
mandatory
Integer32
The number of System Output phase entries.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.15.3.4.13- Type
- scalar
- Access
- readonly
- Status
- mandatory
- Parent
- xPDUSystemOutput
- Siblings
- 13
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| xPDUSystemOutputFrequency mandatory The system output frequency in tenths of Hertz. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.15.3.4.1 |
| xPDUSystemOutputOverCurrentThreshold mandatory Threshold above which an over current condition will be generated.
Specified as a percent of the panel breaker rating.
A value of zero indicates that the threshold is disabled. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.15.3.4.10 |
| xPDUSystemOutputOverCurrentNeutralThreshold mandatory Threshold above which an Over current neutral condition will be generated.
Specified as a percent of the panel breaker rating.
A value of zero indicates that the threshold is disa… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.15.3.4.11 |
| xPDUSystemOutputUnderCurrentThreshold mandatory Threshold below which an under current condition will be generated.
Specified as a percent of the panel breaker rating.
A value of zero indicates that the threshold is disabled. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.15.3.4.12 |
| xPDUSystemOutputPhaseTable mandatory A list of system output table entries.
The number of entries is contained in the
xPDUSystemOutputTableSize OID. | table | - | .1.3.6.1.4.1.318.1.1.15.3.4.14 |
| xPDUSystemOutputNeutralCurrent mandatory Shows the neutral current measured at the system output in tenths of Amps. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.15.3.4.2 |
| xPDUSystemOutputTotalPower mandatory Shows the total system output power in tenths of kW. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.15.3.4.3 |
| xPDUSystemOutputTotalApparentPower mandatory Shows the total system output power in tenths of kVA. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.15.3.4.4 |
| xPDUSystemOutputTotalPowerFactor mandatory Indicates the total power factor of the system output.
A value of 100 representing a unity power factor (1.00).
Measured in hundredths. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.15.3.4.5 |
| xPDUSystemOutputFrequencyTolerance mandatory Shows the circuit panel output frequency tolerance in Hertz. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.15.3.4.6 |
| xPDUSystemOutputMaxKWPower mandatory Defines 100% load in kW.
Purpose is to set to match UPS capabilities. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.15.3.4.7 |
| xPDUSystemOutputOverVoltThreshold mandatory Threshold above which an output over voltage condition will be generated.
Specified as percent deviation from nominal. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.15.3.4.8 |
| xPDUSystemOutputUnderVoltThreshold mandatory Threshold below which an output under voltage condition will be generated.
Specified as percent deviation from nominal.
A value of zero indicates that the threshold is disabled. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.15.3.4.9 |