xATSGeneratorServiceResetRecord
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.18.1.6.7
Object
scalar
mandatory
r/w
Enumeration
Resets the engine start counter, engine run-hours, and kWh values that have accumulated in the generator since last maintenance. Also, the last service date will be reset to the current system date, and any service alarms will be cleared.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.18.1.6.7- Type
- scalar
- Access
- readwrite
- Status
- mandatory
- Parent
- xATSGeneratorService
- Siblings
- 11
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | yes |
2 | no |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| xATSGeneratorServiceTotalRunHoursLifetime mandatory Total time that the generator engine has been run,
over the life of the generator. Measured in hours.
-1 if not available. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.18.1.6.1 |
| xATSGeneratorServiceRunHoursUntilServiceDate mandatory Run hours until the next generator service is due, in hours.
Based on the xATSGeneratorServiceRunHoursThreshold OID
or -1 if the run hour-based threshold is set to off. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.18.1.6.10 |
| xATSGeneratorServiceRunHoursThreshold mandatory Run hour-based service interval. When the run-hours since
service surpasses this threshold, generator service is due. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.18.1.6.11 |
| xATSGeneratorServiceCalendarIntervalThreshold mandatory Calendar-based service interval. When the next service date,
as indicated by the xATSGeneratorServiceNextServiceDate OID
is in the past, generator is due for service. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.18.1.6.12 |
| xATSGeneratorServiceEngineStartsLifetime mandatory Number of engine starts over the life of the generator.
-1 if not available. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.18.1.6.2 |
| xATSGeneratorServiceTotalkWhLifetime mandatory Total kWh of operation over the life of the generator.
-1 if not available. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.18.1.6.3 |
| xATSGeneratorServiceTotalRunHoursSinceMaintenance mandatory Total time that the generator engine has been run,
since last service maintenance. Measured in tenths of hours.
-1 if not available. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.18.1.6.4 |
| xATSGeneratorServiceEngineStartsSinceMaintenance mandatory Number of engine starts since last service maintenance.
-1 if not available. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.18.1.6.5 |
| xATSGeneratorServiceTotalkWhMaintenance mandatory Total kWh of operation since last service maintenance.
-1 if not available. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.18.1.6.6 |
| xATSGeneratorServiceRecordResetDate mandatory Date at which the generator's service record was reset, in dd-mmm-yyyy format. | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.18.1.6.8 |
| xATSGeneratorServiceNextServiceDate mandatory Date at which the next generator service is due in dd-mmm-yyyy format.
Based on the xATSGeneratorServiceCalendarIntervalThreshold OID
or '' if the calendar-based threshold is set … | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.18.1.6.9 |