upsPhaseOutputCurrent
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.1.9.3.3.1.4
Object
column
mandatory
Integer32
The output current in 0.1 amperes drawn by the load on the UPS, or -1 if it's unsupported by this UPS.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.1.9.3.3.1.4- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- upsPhaseOutputPhaseEntry
- Table
- upsPhaseOutputPhaseTable
- Siblings
- 22
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsPhaseOutputPhaseTableIndex mandatory The output identifier. | column | Integer32 | .1.3.6.1.4.1.318.1.1.1.9.3.3.1.1 |
| upsPhaseOutputPercentLoad mandatory The percentage of the UPS load capacity in VA at
redundancy @ (n + x) presently being used on this
output phase, or -1 if it's unsupported by this UPS. | column | Integer32 | .1.3.6.1.4.1.318.1.1.1.9.3.3.1.10 |
| upsPhaseOutputMaxPercentLoad mandatory The maximum percentage of the UPS load capacity in
VA measured at redundancy @ (n + x) presently
being used on this output phase since the last reset
(upsPhaseResetMaxMinValues), … | column | Integer32 | .1.3.6.1.4.1.318.1.1.1.9.3.3.1.11 |
| upsPhaseOutputMinPercentLoad mandatory The minimum percentage of the UPS load capacity in
VA measured at redundancy @ (n + x) presently
being used on this output phase since the last reset
(upsPhaseResetMaxMinValues), … | column | Integer32 | .1.3.6.1.4.1.318.1.1.1.9.3.3.1.12 |
| upsPhaseOutputPower mandatory The output power in Watts, or -1 if it's
unsupported by this UPS. | column | Integer32 | .1.3.6.1.4.1.318.1.1.1.9.3.3.1.13 |
| upsPhaseOutputMaxPower mandatory The maximum output power in Watts measured
since the last reset (upsPhaseResetMaxMinValues), or
-1 if it's unsupported by this UPS.
Sampled every 30 seconds. | column | Integer32 | .1.3.6.1.4.1.318.1.1.1.9.3.3.1.14 |
| upsPhaseOutputMinPower mandatory The minimum output power in Watts measured
since the last reset (upsPhaseResetMaxMinValues), or
-1 if it's unsupported by this UPS.
Sampled every 30 seconds. | column | Integer32 | .1.3.6.1.4.1.318.1.1.1.9.3.3.1.15 |
| upsPhaseOutputPercentPower mandatory The percentage of the UPS power capacity in Watts at
redundancy @ (n + x) presently being used on this
output phase, or -1 if it's unsupported by this UPS. | column | Integer32 | .1.3.6.1.4.1.318.1.1.1.9.3.3.1.16 |
| upsPhaseOutputMaxPercentPower mandatory The maximum percentage of the UPS power capacity
in Watts measured at redundancy @ (n + x) presently
being used on this output phase since the last
reset (upsPhaseResetMaxMinValue… | column | Integer32 | .1.3.6.1.4.1.318.1.1.1.9.3.3.1.17 |
| upsPhaseOutputMinPercentPower mandatory The maximum percentage of the UPS power capacity
in Watts measured at redundancy @ (n + x) presently
being used on this output phase since the last
reset (upsPhaseResetMaxMinValue… | column | Integer32 | .1.3.6.1.4.1.318.1.1.1.9.3.3.1.18 |
| upsPhaseOutputPowerFactor mandatory The Output power factor of the UPS in hundredth. | column | Integer32 | .1.3.6.1.4.1.318.1.1.1.9.3.3.1.19 |
| upsPhaseOutputPhaseIndex mandatory The output phase identifier. | column | Integer32 | .1.3.6.1.4.1.318.1.1.1.9.3.3.1.2 |
| upsPhaseOutputApparentPower mandatory Apparent power in kVA | column | Integer32 | .1.3.6.1.4.1.318.1.1.1.9.3.3.1.20 |
| upsPhaseOutputInverterVoltage mandatory Output voltage in VAC measured at the output of inverter. | column | Integer32 | .1.3.6.1.4.1.318.1.1.1.9.3.3.1.21 |
| upsPhaseOutputVoltagePN mandatory The output voltage measured across Phase to Neutral in VAC, or -1 if it's unsupported
by this UPS. | column | Integer32 | .1.3.6.1.4.1.318.1.1.1.9.3.3.1.22 |
| upsPhaseOutputEnergyUsage mandatory The output energy usage of the phase in hundredths of kWh. | column | Unsigned32 | .1.3.6.1.4.1.318.1.1.1.9.3.3.1.23 |
| upsPhaseOutputVoltage mandatory The output voltage in VAC, or -1 if it's unsupported
by this UPS. | column | Integer32 | .1.3.6.1.4.1.318.1.1.1.9.3.3.1.3 |
| upsPhaseOutputMaxCurrent mandatory The maximum output current in 0.1 amperes measured
since the last reset (upsPhaseResetMaxMinValues), or
-1 if it's unsupported by this UPS.
Sampled every 30 seconds. | column | Integer32 | .1.3.6.1.4.1.318.1.1.1.9.3.3.1.5 |
| upsPhaseOutputMinCurrent mandatory The minimum output current in 0.1 amperes measured
since the last reset (upsPhaseResetMaxMinValues), or
-1 if it's unsupported by this UPS.
Sampled every 30 seconds. | column | Integer32 | .1.3.6.1.4.1.318.1.1.1.9.3.3.1.6 |
| upsPhaseOutputLoad mandatory The output load in VA, or -1 if it's unsupported
by this UPS. | column | Integer32 | .1.3.6.1.4.1.318.1.1.1.9.3.3.1.7 |
| upsPhaseOutputMaxLoad mandatory The maximum output load in VA measured
since the last reset (upsPhaseResetMaxMinValues), or
-1 if it's unsupported by this UPS.
Sampled every 30 seconds. | column | Integer32 | .1.3.6.1.4.1.318.1.1.1.9.3.3.1.8 |
| upsPhaseOutputMinLoad mandatory The minimum output load in VA measured
since the last reset (upsPhaseResetMaxMinValues), or
-1 if it's unsupported by this UPS.
Sampled every 30 seconds. | column | Integer32 | .1.3.6.1.4.1.318.1.1.1.9.3.3.1.9 |