upsParallelSysSwitchGearInstallationLoadPct
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.1.14.13
Object
scalar
mandatory
Integer32
The actual output load expressed as a percentage of the rating of the Parallel UPS system.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.1.14.13- Type
- scalar
- Access
- readonly
- Status
- mandatory
- Parent
- upsParallelSystem
- Siblings
- 18
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsParallelSysLocalAddress mandatory Defines the UPS ID number in the parallel system. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.14.1 |
| upsParallelDiagSubSysBreakerTable mandatory Allows for diagnostics of parallel Circuit Breakers. | table | - | .1.3.6.1.4.1.318.1.1.1.14.10 |
| upsParallelOutputTotalPercentLoad mandatory The percentage of the UPS total load capacity in kVA
or -1 if it's unsupported by this UPS. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.14.11 |
| upsParallelOutputActivePowerTable mandatory A list of output table entries. The number of entries
is given by the value of upsParallelSysRemoteAddress. | table | - | .1.3.6.1.4.1.318.1.1.1.14.12 |
| upsParallelSysRedundancyStatus mandatory Displays the number of backup or redundant UPS devices set up on the parallel system.
nplus0 (1) no redundant units.
nplus1 (2) one redundant unit.
nplus2 (3) two redundant units.… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.14.14 |
| upsParallelSysName mandatory An ID string for the group of UPS units in the same parallel system.
Some products do not allow write operations for this OID. | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.14.15 |
| upsParallelSysUpsTableSize mandatory The number of UPS devices in parallel. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.14.16 |
| upsParallelSysUpsTable mandatory A list of UPS table entries. The number of entries
is given by the value of upsParallelSysUpsTableize. | table | - | .1.3.6.1.4.1.318.1.1.1.14.17 |
| upsParallelNumOfUpsPoweringLoad mandatory Number of UPS powered and protecting the load which are not defective
(no battery fault, no internal fault). | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.14.18 |
| upsParallelMinNumOfRequiredUps mandatory Minimal number of UPS required to guarantee the availability of power. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.14.19 |
| upsParallelSysRemoteAddress mandatory Defines the total number of UPS devices in parallel. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.14.2 |
| upsParallelSysRedundancy mandatory The redundancy warning level for paralleled UPS
nplus0 (1) indicates that there are no redundant units.
nplus1 (2) indicates that there is one redundant unit.
nplus2 (3) indicates… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.14.3 |
| upsParallelInputMaximumCurrent mandatory Maximum input RMS current of the parallel system
measured in Amperes. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.14.4 |
| upsParallelTotalOutputPower mandatory The Total Output power of UPS in kW
when UPS are configured in parallel
or -1 if it's unsupported by this UPS. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.14.5 |
| upsParallelTotalOutputApparentPower mandatory The Total Output Apparent power of UPS in kVA
when UPS are configured in parallel
or -1 if it's unsupported by this UPS. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.14.6 |
| upsParallelInputPhaseTable mandatory A list of input table entries. | table | - | .1.3.6.1.4.1.318.1.1.1.14.7 |
| upsParallelOutputPhaseTable mandatory A list of output table entries. The number of
entries is given by the sum of the upsPhaseNumOutputPhases. | table | - | .1.3.6.1.4.1.318.1.1.1.14.8 |
| upsParallelOutputApparentPowerTable mandatory A list of output table entries. The number of entries
is given by the value of upsOutputNumPhases. | table | - | .1.3.6.1.4.1.318.1.1.1.14.9 |