upsEcoModeCountSinceReset
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.1.20.1.6
Object
scalar
mandatory
Integer32
Number of times UPS entered into ECO mode since maintenance reset.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.1.20.1.6- Type
- scalar
- Access
- readonly
- Status
- mandatory
- Parent
- upsECOmode
- Siblings
- 12
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsEcoModeFreqTransferRange mandatory Indicates tolerance of bypass AC frequency in Hz to switch on ECO mode. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.20.1.1 |
| upsEcoModePercentTimeSinceCommission mandatory Indicates percentage of operation time in ECO mode once product is authorized to use. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.20.1.10 |
| upsEcoModeTotalTimeSinceReset mandatory Total runtime of UPS in ECO mode since maintenance reset (in minutes). | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.20.1.11 |
| upsEcoModeTotalTimeSinceCommission mandatory Total runtime in ECO mode once product is authorized to use (in minutes). | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.20.1.12 |
| upsEcoModeTotalTimeInMonth mandatory Total runtime of UPS in ECO mode since beginning of month (in minutes). | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.20.1.13 |
| upsEcoModeHighVoltThreshold mandatory Indicates high threshold on AC voltage in volts to switch on ECO mode. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.20.1.2 |
| upsEcoModeLowVoltThreshold mandatory Indicates low threshold on AC voltage in volts to switch on ECO mode. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.20.1.3 |
| upsEcoModeSetting mandatory Indicates whether ECO feature is avaiable to this UPS or not. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.20.1.4 |
| upsEcoModeStatus mandatory Indicates whether UPS is running in ECO mode or not. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.20.1.5 |
| upsEcoModeOnlineSinceCommission mandatory Total runtime in online mode with ECO feature enabled once product is authorized to use (in minutes). | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.20.1.7 |
| upsEcoModeOnlineSinceReset mandatory Total runtime in online mode with ECO feature enabled since maintenance reset (in minutes). | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.20.1.8 |
| upsEcoModeTotalPercentTimeSinceReset mandatory Indicates percentage of runtime in ECO mode since maintenance reset. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.20.1.9 |