upsDiagnosticLifeCycleManagement
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.1.13.12
Object
node
No description available.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.1.13.12- Type
- node
- Parent
- upsDiagnostics
- Siblings
- 12
- Children
- 12
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsDiagnosticIM | node | - | .1.3.6.1.4.1.318.1.1.1.13.1 |
| upsDiagnosticSLC | node | - | .1.3.6.1.4.1.318.1.1.1.13.10 |
| upsDiagnosticTemperature | node | - | .1.3.6.1.4.1.318.1.1.1.13.11 |
| upsDiagnosticRelativeHumidity | node | - | .1.3.6.1.4.1.318.1.1.1.13.13 |
| upsDiagnosticPowerModules | node | - | .1.3.6.1.4.1.318.1.1.1.13.2 |
| upsDiagnosticBatteries | node | - | .1.3.6.1.4.1.318.1.1.1.13.3 |
| upsDiagnosticSubsystem | node | - | .1.3.6.1.4.1.318.1.1.1.13.4 |
| upsDiagnosticExternalDevices | node | - | .1.3.6.1.4.1.318.1.1.1.13.5 |
| upsDiagnosticComBus | node | - | .1.3.6.1.4.1.318.1.1.1.13.6 |
| upsDiagnosticPowerCabinet | node | - | .1.3.6.1.4.1.318.1.1.1.13.7 |
| upsDiagnosticDisplay | node | - | .1.3.6.1.4.1.318.1.1.1.13.8 |
| upsDiagnosticUnitController | node | - | .1.3.6.1.4.1.318.1.1.1.13.9 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsDiagLCMDCCapacitorMaintenanceInterval mandatory DC capacitor maintenance interval in days. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.13.12.1 |
| upsDiagLCMAirFilterTimeSinceMaintenance mandatory Air Filter time since last maintenance in days. Note: Some UPS devices
only internally support a higher reporting value such as tenths of months
or even months so this value may … | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.13.12.10 |
| upsDiagLCMWarrantyInterval mandatory Warranty interval in days. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.13.12.11 |
| upsDiagLCMWarrantyElapsedTime mandatory Elapsed Warranty time since system start-up in days. Note: Some UPS devices
only internally support a higher reporting value such as tenths of months
or even months so this value… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.13.12.12 |
| upsDiagLCMDCCapacitorTimeSinceMaintenance mandatory DC capacitor time since last maintenance in days. Note: Some UPS devices
only internally support a higher reporting value such as tenths of months
or even months so this value m… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.13.12.2 |
| upsDiagLCMACCapacitorMaintenanceInterval mandatory AC capacitor maintenance interval in days. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.13.12.3 |
| upsDiagLCMACCapacitorTimeSinceMaintenance mandatory AC capacitor time since last maintenance in days. Note: Some UPS devices
only internally support a higher reporting value such as tenths of months
or even months so this value ma… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.13.12.4 |
| upsDiagLCMBatteryMaintenanceInterval mandatory Battery maintenance interval in days. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.13.12.5 |
| upsDiagLCMBatteryTimeSinceMaintenance mandatory Battery time since last maintenance in days. Note: Some UPS devices
only internally support a higher reporting value such as tenths of months
or even months so this value may jum… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.13.12.6 |
| upsDiagLCMAuxPowerSupplyMaintenanceInterval mandatory Auxiliary Power Supply maintenance interval in days | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.13.12.7 |
| upsDiagLCMAuxPowerSupplyTimeSinceMaintenance mandatory Auxiliary Power Supply time since last maintenance in days. Note: Some UPS devices
only internally support a higher reporting value such as tenths of months
or even months so thi… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.13.12.8 |
| upsDiagLCMAirFilterMaintenanceInterval mandatory Air Filter maintenance interval in days. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.13.12.9 |