upsDiagSwitchGearInputSwitchStatus
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.1.13.5.1.2
Object
scalar
mandatory
Enumeration
The status of the Switch Gear Input Switch. unknown(1) indicates the switch status is unknown. notInstalled(2) indicates the switch is not installed. opened(3) indicates the switch is opened. closed(4) indicates the switch is closed.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.1.13.5.1.2- Type
- scalar
- Access
- readonly
- Status
- mandatory
- Parent
- upsDiagSwitchGear
- Siblings
- 14
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | unknown |
2 | notInstalled |
3 | opened |
4 | closed |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsDiagSwitchGearStatus mandatory The status of the Switch Gear.
unknown(1) indicates the device status is unknown.
notInstalled(2) indicates the device is not installed.
ok(3) indicates the device status is OK.
f… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.13.5.1.1 |
| upsDiagSwitchGearInstallationLoadPct mandatory The actual output load expressed as a percentage of the rating of the UPS. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.13.5.1.10 |
| upsDiagSubFeedPhaseTable mandatory A list of subfeed phase table. | table | - | .1.3.6.1.4.1.318.1.1.1.13.5.1.11 |
| upsDiagSwitchgearSerialNumber mandatory The serial number of the UPS I/O Cabinet. | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.5.1.12 |
| upsDiagSwitchgearAmbientTemperature mandatory The ambient temperature of I/O Cabinet in tenths of degrees Celsius. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.13.5.1.13 |
| upsDiagUsrSuppSwitchgearMonitorTableSize mandatory The number of user supplied Switch Gear Monitor Boards attached to the UPS. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.13.5.1.14 |
| upsDiagUsrSuppSwitchgearMonitorTable mandatory Allows for diagnostics of the user supplied Switch Gear Monitor Board. | table | - | .1.3.6.1.4.1.318.1.1.1.13.5.1.15 |
| upsDiagSwitchGearOutputSwitchStatus mandatory The status of the Switch Gear Output Switch.
unknown(1) indicates the switch status is unknown.
notInstalled(2) indicates the switch is not installed.
opened(3) indicates the swit… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.13.5.1.3 |
| upsDiagSwitchGearBypassSwitchStatus mandatory The status of the Switch Gear Bypass Switch.
unknown(1) indicates the switch status is unknown.
notInstalled(2) indicates the switch is not installed.
opened(3) indicates the swit… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.13.5.1.4 |
| upsDiagSwitchGearBypassInputSwitchStatus mandatory The status of the Switch Gear Bypass Input Switch.
unknown(1) indicates the switch status is unknown.
notInstalled(2) indicates the switch is not installed.
opened(3) indicates th… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.13.5.1.5 |
| upsDiagSwitchGearBreakerTableSize mandatory The number of switchgear breakers attached to the UPS. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.13.5.1.6 |
| upsDiagSwitchGearBreakerTable mandatory Switchgear breaker table. | table | - | .1.3.6.1.4.1.318.1.1.1.13.5.1.7 |
| upsDiagSubFeedBreakerTableSize mandatory The number of subfeed breakers attached to the UPS. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.13.5.1.8 |
| upsDiagSubFeedBreakerTable mandatory Subfeed breaker table. | table | - | .1.3.6.1.4.1.318.1.1.1.13.5.1.9 |