upsDiagSubSysExternalConnectorStatus
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.1.13.4.34
Object
scalar
mandatory
Enumeration
The status of the external connector board. unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device status is on and OK. offFail(5) indicates the device status is off and failed. onFail(6) indicates the device status is on and failed. lostComm(7) indicates the device has lost communication.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.1.13.4.34- Type
- scalar
- Access
- readonly
- Status
- mandatory
- Parent
- upsDiagnosticSubsystem
- Siblings
- 37
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | unknown |
2 | notInstalled |
3 | offOk |
4 | onOk |
5 | offFail |
6 | onFail |
7 | lostComm |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsDiagSubSysFrameTableSize mandatory The number of frames attached to the UPS including the Main frame. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.13.4.1 |
| upsDiagSubSysDisplayInterfaceCardTable mandatory Allows for diagnostics of individual Display Interface Cards. | table | - | .1.3.6.1.4.1.318.1.1.1.13.4.10 |
| upsDiagSubSysDCCircuitBreakerTableSize mandatory The number of DC Circuit Breakers attached to the UPS. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.13.4.11 |
| upsDiagSubSysDCCircuitBreakerTable mandatory Allows for diagnostics of individual DC Circuit Breakers. | table | - | .1.3.6.1.4.1.318.1.1.1.13.4.12 |
| upsDiagSubSysSystemPowerSupplyTableSize mandatory The number of System Power Supplies attached to the UPS. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.13.4.13 |
| upsDiagSubSysSystemPowerSupplyTable mandatory Allows for diagnostics of individual System Power Supplies. | table | - | .1.3.6.1.4.1.318.1.1.1.13.4.14 |
| upsDiagSubSysXRCommunicationCardTableSize mandatory The number of XR Communication Cards attached to the UPS. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.13.4.15 |
| upsDiagSubSysXRCommunicationCardTable mandatory Allows for diagnostics of individual XR Communication Cards. | table | - | .1.3.6.1.4.1.318.1.1.1.13.4.16 |
| upsDiagSubSysExternalPowerFrameBoardTableSize mandatory The number of External Power Frame Boards attached to the UPS. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.13.4.17 |
| upsDiagSubSysExternalPowerFrameBoardTable mandatory Allows for diagnostics of individual External Power Frame Boards. | table | - | .1.3.6.1.4.1.318.1.1.1.13.4.18 |
| upsDiagSubSysChargerTableSize mandatory The number of Chargers attached to the UPS. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.13.4.19 |
| upsDiagSubSysFrameTable mandatory Allows for diagnostics of individual XR Frames. | table | - | .1.3.6.1.4.1.318.1.1.1.13.4.2 |
| upsDiagSubSysChargerTable mandatory Allows for diagnostics of individual chargers. | table | - | .1.3.6.1.4.1.318.1.1.1.13.4.20 |
| upsDiagSubSysInverterTableSize mandatory The number of Inverters attached to the UPS. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.13.4.21 |
| upsDiagSubSysInverterTable mandatory Allows for diagnostics of individual Inverters. | table | - | .1.3.6.1.4.1.318.1.1.1.13.4.22 |
| upsDiagSubSysPowerFactorCorrectionTableSize mandatory The number of Power Factor Correction devices attached to the UPS. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.13.4.23 |
| upsDiagSubSysPowerFactorCorrectionTable mandatory Allows for diagnostics of individual PowerFactorCorrections. | table | - | .1.3.6.1.4.1.318.1.1.1.13.4.24 |
| upsDiagSubSysNetworkComCardTableSize mandatory The number of Network Communication Cards attached to the UPS. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.13.4.25 |
| upsDiagSubSysNetworkComCardTable mandatory Allows for getting diagnostics information of an individual Network Communication Card. | table | - | .1.3.6.1.4.1.318.1.1.1.13.4.26 |
| upsDiagSubSysUsrSuppBattMonitorTableSize mandatory The number of user supplied Battery Monitor Boards attached to the UPS. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.13.4.27 |
| upsDiagSubSysUsrSuppBattMonitorTable mandatory Allows for diagnostics of the user supplied Battery Monitor Board. | table | - | .1.3.6.1.4.1.318.1.1.1.13.4.28 |
| upsDiagSubSysUsrSuppBattBreakerStatus mandatory The status of the user supplied Battery Breaker.
unknown(1) indicates the circuit breaker status is unknown.
notInstalled(2) indicates the circuit breaker is not installed.
opened… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.13.4.29 |
| upsDiagSubSysIntBypSwitchTableSize mandatory The number of Internal Bypass switches attached to the UPS. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.13.4.3 |
| upsDiagSubSysPSUTableSize mandatory The number of Power Supply Units in the UPS. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.13.4.30 |
| upsDiagSubSysPSUTable mandatory Allows for diagnostics of individual Power Supply Units. The number of
entries is contained in the upsDiagSubSysPSUTableSize OID. | table | - | .1.3.6.1.4.1.318.1.1.1.13.4.31 |
| upsDiagSubSysIDRCTableSize mandatory The number of ID and Relay Controller Cards attached to the UPS. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.13.4.32 |
| upsDiagSubSysIDRCTable mandatory Allows for diagnostics of the ID and Relay Controller Card. | table | - | .1.3.6.1.4.1.318.1.1.1.13.4.33 |
| upsDiagSubSysBackfeedContactorTableSize mandatory The number of backfeed protection contactor attached to the UPS. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.13.4.35 |
| upsDiagSubSysBackfeedContactorTable mandatory Backfeed protection contactor table. | table | - | .1.3.6.1.4.1.318.1.1.1.13.4.36 |
| upsDiagSubSysIntBypSwitchFanLifetimeInfoTableSize mandatory The number of backfeed protection contactor attached to the UPS. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.13.4.37 |
| upsDiagSubSysIntBypSwitchFanLifetimeInfoTable mandatory Allows for diagnostics of the Internal Bypass Switch life time infomation. | table | - | .1.3.6.1.4.1.318.1.1.1.13.4.38 |
| upsDiagSubSysIntBypSwitchTable mandatory Allows for diagnostics of the Internal Bypass Switch. | table | - | .1.3.6.1.4.1.318.1.1.1.13.4.4 |
| upsDiagSubSysBattMonitorTableSize mandatory The number of Battery Monitor Boards attached to the UPS. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.13.4.5 |
| upsDiagSubSysBattMonitorTable mandatory Allows for diagnostics of the Battery Monitor Board. | table | - | .1.3.6.1.4.1.318.1.1.1.13.4.6 |
| upsDiagSubSysExternalSwitchGearTableSize mandatory The number of External Switch Gears attached to the UPS. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.13.4.7 |
| upsDiagSubSysExternalSwitchGearTable mandatory Allows for diagnostics of the individual External Switch Gear. | table | - | .1.3.6.1.4.1.318.1.1.1.13.4.8 |
| upsDiagSubSysDisplayInterfaceCardTableSize mandatory The number of Display Interface Cards attached to the UPS. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.13.4.9 |