upsDiagBatteryModuleStatusPerFrame

PowerNet-MIB · .1.3.6.1.4.1.318.1.1.1.13.3.4.1.2

Object

column mandatory RFC1213-MIBDisplayString
An ASCII string containing the 64 flags representing
the status of battery modules. 1 indicates battery module installed,
0 indicates battery module not installed.
              
The flags are numbered from 1 to 64, and read from left
to right. The flags are defined as follows:
              
Flag  1: Battery Module Level 1 A
Flag  2: Battery Module Level 1 B
Flag  3: Battery Module Level 1 C
Flag  4: Battery Module Level 1 D
Flag  5: Battery Module Level 1 E
Flag  6: Battery Module Level 1 F
              
Flag  7: Battery Module Level 2 A
Flag  8: Battery Module Level 2 B
Flag  9: Battery Module Level 2 C
Flag 10: Battery Module Level 2 D
Flag 11: Battery Module Level 2 E
Flag 12: Battery Module Level 2 F
              
Flag 13: Battery Module Level 3 A
Flag 14: Battery Module Level 3 B
Flag 15: Battery Module Level 3 C
Flag 16: Battery Module Level 3 D
Flag 17: Battery Module Level 3 E
Flag 18: Battery Module Level 3 F
              
Flag 19: Battery Module Level 4 A
Flag 20: Battery Module Level 4 B
Flag 21: Battery Module Level 4 C
Flag 22: Battery Module Level 4 D
Flag 23: Battery Module Level 4 E
Flag 24: Battery Module Level 4 F
              
Flag 25: Battery Module Level 7 A
Flag 26: Battery Module Level 7 B
Flag 27: Battery Module Level 7 C
Flag 28: Battery Module Level 7 D
Flag 29: Battery Module Level 7 E
Flag 30: Battery Module Level 7 F
              
Flag 31: Battery Module Level 8 A
Flag 32: Battery Module Level 8 B
Flag 33: Battery Module Level 8 C
Flag 34: Battery Module Level 8 D
Flag 35: Battery Module Level 8 E
Flag 36: Battery Module Level 8 F
              
Flag 37: Battery Module Level 9 A
Flag 38: Battery Module Level 9 B
Flag 39: Battery Module Level 9 C
Flag 40: Battery Module Level 9 D
Flag 41: Battery Module Level 9 E
Flag 42: Battery Module Level 9 F
              
Flag 43: Battery Module Level 10 A
Flag 44: Battery Module Level 10 B
Flag 45: Battery Module Level 10 C
Flag 46: Battery Module Level 10 D
Flag 47: Battery Module Level 10 E
Flag 48: Battery Module Level 10 F
              
Flag 49: <Not Used>
Flag 50: <Not Used>
Flag 51: <Not Used>
Flag 52: <Not Used>
Flag 53: <Not Used>
Flag 54: <Not Used>
              
Flag 55: <Not Used>
Flag 56: <Not Used>
Flag 57: <Not Used>
Flag 58: <Not Used>
Flag 59: <Not Used>
Flag 60: <Not Used>
              
Flag 61: <Not Used>
Flag 62: <Not Used>
Flag 63: <Not Used>
Flag 64: <Not Used>

Context

MIB
PowerNet-MIB
OID
.1.3.6.1.4.1.318.1.1.1.13.3.4.1.2
Type
column
Access
readonly
Status
mandatory
Parent
upsDiagBatteryFrameEntry
Table
upsDiagBatteryFrameTable
Siblings
4

Syntax

RFC1213-MIBDisplayString
Source
RFC1213-MIBDisplayString
Base type
OctetString

Values & Constraints

No enumerated values or constraints recorded.

Related Objects

Sibling Objects