upsAdvOutputLoad
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.1.4.2.3
Object
The current UPS load expressed in percent of rated capacity.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.1.4.2.3- Type
- scalar
- Access
- readonly
- Status
- mandatory
- Parent
- upsAdvOutput
- Siblings
- 21
Syntax
RFC1155-SMIGauge
- Source
- RFC1155-SMIGauge
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsAdvOutputVoltage mandatory The output voltage of the UPS system in VAC. | scalar | RFC1155-SMIGauge | .1.3.6.1.4.1.318.1.1.1.4.2.1 |
| upsAdvOutputStatisticsTable mandatory A list of input table entries. The number of entries
is given by the value of upsPhaseNumOutputs. | table | - | .1.3.6.1.4.1.318.1.1.1.4.2.10 |
| upsAdvOutputNeutralCurrent mandatory The neutral current in amperes. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.4.2.11 |
| upsAdvOutputEnergyUsage mandatory The output energy usage of the UPS in kWh. | scalar | Unsigned32 | .1.3.6.1.4.1.318.1.1.1.4.2.12 |
| upsAdvOutputSourceSynchronization mandatory Indicates the synchronization source for the inverter output frequency.
1. Main
2. Internal
3. External
4. On AC Bypass.
5. External / On Bypass
For other values it is unknown | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.4.2.13 |
| upsAdvOutputInverterFrequency mandatory Output frequency in Hz measured at the output of inverter. | scalar | RFC1155-SMIGauge | .1.3.6.1.4.1.318.1.1.1.4.2.14 |
| upsAdvOutputInverterLoad mandatory The total active power at the output of all inverter modules in percent of rated system power (% of kW)
If not supported, return -1. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.4.2.15 |
| upsAdvOutputPercentPower mandatory The relative active power at the output of the inverter system (static switch output) in percent of rated system power (% of kW).
If not supported, return -1. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.4.2.16 |
| upsAdvOutputInverterActivePower mandatory The total active power at the output of all inverter modules in kW.
If not supported, return -1. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.4.2.17 |
| upsAdvOutputPercentLoad mandatory The relative apparent power at the output of the inverter system (static switch output) in percent of rated system load (% of kVA)
If not supported, return -1. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.4.2.18 |
| upsAdvOutputInverterCurrent mandatory The current, in amperes, drawn by the load on the inverter. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.4.2.19 |
| upsAdvOutputFrequency mandatory The current output frequency of the UPS system in Hz. | scalar | RFC1155-SMIGauge | .1.3.6.1.4.1.318.1.1.1.4.2.2 |
| upsAdvOutputReactivePower mandatory The total output reactive power of all phases of the UPS system in VAR.
If not supported, return -1. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.4.2.20 |
| upsAdvOutputInverterVoltage mandatory The output voltage of the inverter in VAC. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.4.2.21 |
| upsAdvOutputUpperAcceptPowerSettingPct mandatory Upper acceptable voltage as percent of nominal voltage | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.4.2.22 |
| upsAdvOutputCurrent mandatory The current in amperes drawn by the load on the UPS. | scalar | RFC1155-SMIGauge | .1.3.6.1.4.1.318.1.1.1.4.2.4 |
| upsAdvOutputRedundancy mandatory The number of power modules which can fail or be
removed without causing the UPS to generate a Minimum
Redundancy Lost event. | scalar | RFC1155-SMIGauge | .1.3.6.1.4.1.318.1.1.1.4.2.5 |
| upsAdvOutputKVACapacity mandatory The maximum load that this UPS can support.
This value is dynamic for scalable 3-phase UPS devices where power modules can be added for increased capacity.
The value indicates the… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.4.2.6 |
| upsAdvOutputNominalFrequency mandatory The nominal output frequency of the UPS system in Hz. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.4.2.7 |
| upsAdvOutputActivePower mandatory The total output active power of the UPS system in W.
The total active power is the sum of phase 1, phase 2 and
phase 3 power. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.4.2.8 |
| upsAdvOutputApparentPower mandatory The total output apparent power of all phases of the UPS system in VA.
If not supported, return -1. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.4.2.9 |