upsAdvConfigOutputFreqRange

PowerNet-MIB · .1.3.6.1.4.1.318.1.1.1.5.2.19

Object

scalar mandatory r/w Enumeration
Configure the output frequency tolerance range.
unknown(1) indicates the output frequency is unknown.
freqRangeAUTO(2) configure the output frequency range for automatic.
freqRange60Var1(3) configure the output frequency range for 60 +/- 0.1 Hz
freqRange60Var3(4) configure the output frequency range for 60 +/- 3.0 Hz
freqRange50Var1(5) configure the output frequency range for 50 +/- 0.1 Hz
freqRange50Var3(6) configure the output frequency range for 50 +/- 3.0 Hz
freqRange60Var10(7) configure the output frequency range for 60 +/- 10 Hz
freqRange50Var10(8) configure the output frequency range for 50 +/- 10 Hz
freqRange60Var1dot0(9) configure the output frequency range for 60 +/- 1.0 Hz
freqRange50Var1dot0(10) configure the output frequency range for 50 +/- 1.0 Hz
freqRange50Pct0dot5(11) configure the output frequency range for 50 Hz +/- 0.5 %
freqRange50Pct1(12) configure the output frequency range for 50 Hz +/- 1.0 %
freqRange50Pct2(13) configure the output frequency range for 50 Hz +/- 2.0 %
freqRange50Pct4(14) configure the output frequency range for 50 Hz +/- 4.0 %
freqRange50Pct6(15) configure the output frequency range for 50 Hz +/- 6.0 %
freqRange50Pct8(16) configure the output frequency range for 50 Hz +/- 8.0 %
freqRange60Pct0dot5(17) configure the output frequency range for 60 Hz +/- 0.5 %
freqRange60Pct1(18) configure the output frequency range for 60 Hz +/- 1.0 %
freqRange60Pct2(19) configure the output frequency range for 60 Hz +/- 2.0 %
freqRange60Pct4(20) configure the output frequency range for 60 Hz +/- 4.0 %
freqRange60Pct6(21) configure the output frequency range for 60 Hz +/- 6.0 %
freqRange60Pct8(22) configure the output frequency range for 60 Hz +/- 8.0 %
freqRange50Var4(23) configure the output frequency range for 50 +/- 4.0 Hz
freqRange60Var4(24) configure the output frequency range for 60 +/- 4.0 Hz
For a list of allowed values and conditions when variable can be set by your UPS model,
see the UPS User's Manual.

Context

MIB
PowerNet-MIB
OID
.1.3.6.1.4.1.318.1.1.1.5.2.19
Type
scalar
Access
readwrite
Status
mandatory
Parent
upsAdvConfig

Syntax

Enumeration

Values & Constraints

Enumerated Values
1unknown
2freqRangeAUTO
3freqRange60Var1
4freqRange60Var3
5freqRange50Var1
6freqRange50Var3
7freqRange60Var10
8freqRange50Var10
9freqRange60Var1dot0
10freqRange50Var1dot0
11freqRange50Pct0dot5
12freqRange50Pct1
13freqRange50Pct2
14freqRange50Pct4
15freqRange50Pct6
16freqRange50Pct8
17freqRange60Pct0dot5
18freqRange60Pct1
19freqRange60Pct2
20freqRange60Pct4
21freqRange60Pct6
22freqRange60Pct8
23freqRange50Var4
24freqRange60Var4