upsAdvConfigAutoShutdownControlSkipOffDelay
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.1.5.2.62
Object
scalar
mandatory
r/w
Enumeration
Configures whether the UPS device's off delay setting (upsAdvConfigShutoffDelay) will be used for automatic shutdown.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.1.5.2.62- Type
- scalar
- Access
- readwrite
- Status
- mandatory
- Parent
- upsAdvConfig
- Siblings
- 79
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | upsAdvConfigSkipOffDelayAutoShutdown |
2 | upsAdvConfigUseOffDelayAutoShutdown |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsAdvConfigRatedOutputVoltage mandatory The nominal output voltage from the UPS in VAC.
For a list of allowed values supported by your UPS model,
see the UPS User's Manual.
If a value other than a … | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.1 |
| upsAdvConfigShutoffDelay mandatory The delay in seconds the UPS remains on after being told
to turn off.
For a list of allowed values supported by your UPS model,
see the UPS User's Manual.
If… | scalar | RFC1155-SMITimeTicks | .1.3.6.1.4.1.318.1.1.1.5.2.10 |
| upsAdvConfigUpsSleepTime mandatory The time in seconds for the UPS to go to 'sleep' when
instructed. When in sleep mode, the UPS will not provide
output power regardless of the input line state. Once the
specifie… | scalar | RFC1155-SMITimeTicks | .1.3.6.1.4.1.318.1.1.1.5.2.11 |
| upsAdvConfigSetEEPROMDefaults mandatory WRITE: Resets the UPS EEPROM variables to default values.
READ: returns 1 | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.5.2.12 |
| upsAdvConfigDipSwitchTable mandatory Current settings of UPS dip switches. | table | - | .1.3.6.1.4.1.318.1.1.1.5.2.13 |
| upsAdvConfigBattExhaustThresh mandatory The number of seconds prior to battery exhaustion when the
UPS will switch off power to its load. | scalar | RFC1155-SMITimeTicks | .1.3.6.1.4.1.318.1.1.1.5.2.14 |
| upsAdvConfigPassword mandatory The password entered at the UPS front panel to enable local
configuration of the EEProm. If the password is disabled or
is not supported, then the agent returns a null string. | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.5.2.15 |
| upsAdvConfigAllowedSetTable mandatory The table listing the allowed values for all discrete
configurable UPS variables. | table | - | .1.3.6.1.4.1.318.1.1.1.5.2.16 |
| upsAdvConfigBattCabAmpHour mandatory Configure the amp-hour setting of the UPS battery solution.
The value shows the maximum battery capacity configured for the UPS when using a third party battery solution
regardles… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.17 |
| upsAdvConfigPositionSelector mandatory Configure UPS position selector. If the UPS doesn't
support this configuration it will report unknown (1).
The positions are either rack (2) for rack mounted or
tower (3) for tow… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.5.2.18 |
| upsAdvConfigOutputFreqRange mandatory Configure the output frequency tolerance range.
unknown(1) indicates the output frequency is unknown.
freqRangeAUTO(2) configure the output frequency range for automatic.
freqRang… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.5.2.19 |
| upsAdvConfigHighTransferVolt mandatory The maximum line voltage in VAC allowed before the
UPS system transfers to battery backup.
For a list of allowed values supported by your UPS model,
see the UPS User's … | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.2 |
| upsAdvConfigUPSFail mandatory Configure the UPS fail action. If UPS fails,
and frequency or voltage is out of range it will either
GotoBypass (2) or DropLoad (3). This OID will report
unknown (1) if it is no… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.5.2.20 |
| upsAdvConfigAlarmRedundancy mandatory Configure settings of UPS alarm if the redundancy is
under the current redundancy. Use 0 for never. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.21 |
| upsAdvConfigAlarmLoadOver mandatory Configure settings of UPS alarm if the load is
over the current load in kVA. Use -1 for never. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.22 |
| upsAdvConfigAlarmRuntimeUnder mandatory Configure settings of UPS alarm if the runtime is
under the current time of minutes. Use -1 for never. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.23 |
| upsAdvConfigVoutReporting mandatory Configure the way the UPS scales its output voltage readings.
unknown(1) indicates the Vout Reporting is unknown.
voutAUTO(2) configure the Vout Reporting for automatic scaling.
v… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.5.2.24 |
| upsAdvConfigNumExternalBatteries mandatory Configure the number of external batteries connected to the UPS. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.25 |
| upsAdvConfigSimpleSignalShutdowns mandatory Configure Simple Signal shutdown commands from the Simple Signal
port to be issued to the UPS.
unknown(1) indicates the Simple Signal Shutdown setting is unknown.
disabled(2) conf… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.5.2.26 |
| upsAdvConfigMaxShutdownTime mandatory The maximum amount of time for server shutdown to complete before a
UPS shutdown occurs. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.27 |
| upsAsiUpsControlServerRequestShutdown mandatory Start a server shutdown sequence:
serverShutdownOff: Shutdown server and turn off UPS
serverShutdownReboot: Shutdown server and turn reboot UPS. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.5.2.28 |
| upsAdvConfigMinReturnRuntime mandatory The minimum amount of run time in seconds required before the output will be
turned on, using power calculation captured at start of last shutdown. | scalar | RFC1155-SMITimeTicks | .1.3.6.1.4.1.318.1.1.1.5.2.29 |
| upsAdvConfigLowTransferVolt mandatory The minimum line voltage in VAC allowed before the
UPS system transfers to battery backup.
For a list of allowed values supported by your UPS model,
see the UPS User's … | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.3 |
| upsAdvConfigBasicSignalLowBatteryDuration mandatory The duration of runtime in seconds during an on-battery condition at which
the UPS will signal the basic low battery shutdown condition. | scalar | RFC1155-SMITimeTicks | .1.3.6.1.4.1.318.1.1.1.5.2.30 |
| upsAdvConfigBypassPhaseLockRequired mandatory Sets the condition for when bypass is an acceptable mode of operation as a
requirement. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.5.2.31 |
| upsAdvConfigOutputFreqSlewRate mandatory The rate at which the UPS will change its output frequency
in response to utility frequency changes. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.5.2.32 |
| upsAdvConfigChargerLevel mandatory Sets the rate at which the UPS charges its batteries. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.5.2.33 |
| upsAdvConfigBypassToleranceSetting mandatory This setting allows selecting from standard bypass tolerance configurations to suit their situation. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.5.2.34 |
| upsAdvConfigMainsSetting mandatory Configure the type of mains supply system.
singleInput (1) indicates a single supply system.
dualInput (2) indicates a dual supply system. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.5.2.35 |
| upsAdvConfigACWiringSetting mandatory Configure the AC wiring of the system.
threeWire (1) indicates 3-wire system configuration.
fourWire (2) indicates 4-wire system configuration.
fourWireHRG (3) indicates a 4-wire… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.5.2.36 |
| upsAdvConfigUpperOutputVoltTolerance mandatory Upper tolerance of the output RMS voltage before transferring to bypass.
Expressed as percent of nominal voltage. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.37 |
| upsAdvConfigLowerOutputVoltTolerance mandatory Lower tolerance of the output RMS voltage before transferring to bypass.
Expressed as percent of nominal voltage. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.38 |
| upsAdvConfigUpperBypassVoltTolerance mandatory Upper tolerance of the bypass voltage that allows transfer to bypass by user.
Expressed as percent of nominal voltage. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.39 |
| upsAdvConfigAlarm mandatory A flag indicating how the UPS should handle audible
line fail alarms:
timed(1): UPS alarm will sound after a preset timed duration starting
from the line fail condition (see OID u… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.5.2.4 |
| upsAdvConfigLowerBypassVoltTolerance mandatory Lower tolerance of the bypass voltage that allows transfer to bypass by user.
Expressed as percent of nominal voltage. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.40 |
| upsAdvConfigOutofSyncBypassTransferDelay mandatory Configure the time (in milliseconds), indicating the gap in output voltage
if an asynchronous transfer to bypass needs to occur. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.41 |
| upsAdvConfigWarningAlarmDelay mandatory Configure the time delay for reporting warning alarms
(in seconds). | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.43 |
| upsAdvConfigInformationalAlarmDelay mandatory Configure the time delay for reporting informational alarms
(in seconds). | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.44 |
| upsAdvConfigGreenMode mandatory Enable/Disable UPS green mode feature. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.5.2.45 |
| upsAdvConfigLCDLocalLanguage mandatory Configure the language setting of the UPS LCD display information. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.5.2.46 |
| upsAdvConfigLCDLockOut mandatory Enable/Disable the control function of the UPS via the LCD Display. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.5.2.47 |
| upsAdvConfigChargerRate mandatory Change the maximum allowed UPS charge rate on select products where 100% represents
the manufacturer's recommended rate. A charge/discharge rate of C/10 for a 10 Ah
battery would… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.48 |
| upsAdvConfigBatterySelection mandatory Configure the installed battery type; VRLA is a Valve Regulated
Lead Acid type battery, Vented Cell is a wet cell type (car) battery, NiCd is a
Nickel-Cadmium type battery, and Li… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.5.2.49 |
| upsAdvConfigAlarmTimer mandatory The time after initial line failure at which the UPS
begins emitting audible alarms (beeping). This timer is
observed only if the value of extControlAlarm is timed(2).
Allowed va… | scalar | RFC1155-SMITimeTicks | .1.3.6.1.4.1.318.1.1.1.5.2.5 |
| upsAdvConfigBatteryHealthAlarmWarningTime mandatory Configure the number of days before the battery health is depleted that the battery
health alarm is activated. Setting this to -1, if supported by the UPS, will suppress
the batte… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.50 |
| upsAdvConfigBatteryHealthAlarmSleepTime mandatory Configure the number of days that the UPS device's battery health alarm should sleep before
being activated again after being acknowledged. Setting this to -1, if supported by the… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.51 |
| upsAdvConfigSignalFlashVoltage mandatory Configure the signal flash voltage in tenths of volts. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.52 |
| upsAdvConfigBatteryTemperatureCompensation mandatory Configure the battery temperature compensation voltage in
hundreds of volts per degree C. On products which support this
field, the charger voltage is reduced for each degree C ri… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.53 |
| upsAdvConfigBatteryChargerType mandatory This OID describes type of battery charger used: standard or extended.
1 - Internal charger,
2 - Extended (CLA),
3 - Large extension (other cases),
4 - Extra large extension (XL),… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.54 |
| upsAdvConfigAutomaticRestart mandatory Indicates whether Automatic Restart is enabled or disabled. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.5.2.55 |
| upsAdvConfigDeepDischargeProtection mandatory Indicates whether protection against deep discharge is enabled or disabled. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.5.2.56 |
| upsAdvConfigFreqBypassTransferRange mandatory Tolerance of bypass AC frequency to switch on bypass. The frequency must be in
range of -X% to +X% around the nominal value. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.57 |
| upsAdvConfigUpsPowerconverterType mandatory This value indicates the type of UPS in terms of output phase and redundancy.
2 - Galaxy 7000 Unitary 3:3
3 - Galaxy 7000 Redundant 3:3
4 - Galaxy 7000 Parallel SSC 3:3
6 - Ga… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.58 |
| upsAdvConfigFrequencyConverterMode mandatory Indicates whether the output frequency is in Auto Ranging or Frequency converter mode.
In Auto Ranging mode the inverter provides output frequency in the same range as the input.
… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.5.2.59 |
| upsAdvConfigMinReturnCapacity mandatory The minimum battery capacity required before the UPS will
return from a low battery shutdown condition. The capacity is
measured from 0% battery capacity (or Low Battery) as a pe… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.6 |
| upsAdvConfigACQualificationTime mandatory The time in seconds that the voltage is required to be in the acceptable range before being declared to be acceptable. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.60 |
| upsAdvConfigRebootDuration mandatory During a reboot sequence, power is turned off and then
back on. This OID defines the minimum amount of time to wait
(seconds) after turning the power off, at the start
of the sequ… | scalar | RFC1155-SMITimeTicks | .1.3.6.1.4.1.318.1.1.1.5.2.61 |
| upsAdvConfigAutoShutdownControlAutoRestart mandatory Configures whether the UPS will automatically restart
after an automatic shutdown. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.5.2.63 |
| upsAdvConfigAutoShutdownControlTimeOnBattery mandatory Configures whether the UPS will turn off automatically
after the UPS device's time on battery has exceeded the
upsAdvConfigAutoShutdownTimeOnBattery OID setting. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.5.2.64 |
| upsAdvConfigAutoShutdownControlRuntimeRemaining mandatory Configures whether the UPS will turn off when the UPS
is on battery and the remaining runtime is less than
the upsAdvConfigAutoShutdownRuntimeRemaining OID
setting. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.5.2.65 |
| upsAdvConfigAutoShutdownTimeOnBattery mandatory When the UPS has been on battery for more time than this
value, the UPS will turn off if this condition is
enabled by the upsAdvConfigAutoShutdownControlTimeOnBattery
OID. | scalar | RFC1155-SMITimeTicks | .1.3.6.1.4.1.318.1.1.1.5.2.66 |
| upsAdvConfigAutoShutdownRuntimeRemaining mandatory When the UPS runtime remaining is less than this setting,
the UPS will turn off if this condition is enabled by the
upsAdvConfigAutoShutdownControlRuntimeRemaining OID. | scalar | RFC1155-SMITimeTicks | .1.3.6.1.4.1.318.1.1.1.5.2.67 |
| upsAdvConfigHighLLTransferVolt mandatory The maximum line to line voltage in VAC allowed before the
UPS system transfers to battery backup.
For a list of allowed values supported by your UPS model,
see the UPS… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.68 |
| upsAdvConfigLowLLTransferVolt mandatory The minimum line to line voltage in VAC allowed before the
UPS system transfers to battery backup.
For a list of allowed values supported by your UPS model,
see the UPS… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.69 |
| upsAdvConfigSensitivity mandatory The sensitivity of the UPS to utility line abnormalities
or noises. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.5.2.7 |
| upsAdvConfigHighBypassTransferVolt mandatory The maximum line voltage, in VAC, that the
UPS system will allow a transfer to bypass. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.70 |
| upsAdvConfigLowBypassTransferVolt mandatory The minimum line voltage, in VAC, that the
UPS system will allow a transfer to bypass. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.71 |
| upsAdvConfigHighBypassLLTransferVolt mandatory The maximum line to line voltage, in VAC, that the
UPS system will allow a transfer to bypass. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.72 |
| upsAdvConfigLowBypassLLTransferVolt mandatory The minimum line to line voltage, in VAC, that the
UPS system will allow a transfer to bypass. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.73 |
| upsAdvConfigAutoShutdownControlBatteryCapacity mandatory This setting only shuts down the UPS when the UPS is on battery and
when the battery capacity is less than the
upsAdvConfigAutoShutdownBatteryCapacity OID setting. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.5.2.74 |
| upsAdvConfigAutoShutdownBatteryCapacity mandatory When the Battery capacity is less than this value,
the UPS will turn off, if this condition is enabled by
upsAdvConfigAutoShutdownControlBatteryCapacity OID
setting. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.75 |
| upsAdvConfigAutoShutdownControlLoadPercentOnUps mandatory This setting only shuts down the UPS when the UPS is on battery and
when the load percent on UPS is less than the
upsAdvConfigAutoShutdownLoadPercentOnUps OID setting. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.5.2.76 |
| upsAdvConfigAutoShutdownLoadPercentOnUps mandatory When the Load percent on UPS is less than this value,
the UPS will turn off, if this condition is enabled by the
upsAdvConfigAutoShutdownControlLoadPercentOnUps OID
setting. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.77 |
| upsAdvConfigBypassFrequencyRangeLowerLimit mandatory Lower Limit of Bypass Frequency Range in Hz. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.78 |
| upsAdvConfigBypassFrequencyRangeUpperLimit mandatory Upper Limit of Bypass Frequency Range in Hz. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.79 |
| upsAdvConfigLowBatteryRunTime mandatory The desired run time of the UPS, in seconds, once the
low battery condition is reached. During this time the UPS may
produce a constant warning tone, which cannot be disabled,
dep… | scalar | RFC1155-SMITimeTicks | .1.3.6.1.4.1.318.1.1.1.5.2.8 |
| upsAdvConfigEcoVoltageRangeLowerLimit mandatory Lower Limit of ECO Voltage Range in Volts. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.80 |
| upsAdvConfigEcoVoltageRangeUpperLimit mandatory Upper Limit of ECO Voltage Range in Volts. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.5.2.81 |
| upsAdvConfigReturnDelay mandatory The delay in seconds after utility line power returns
before the UPS will turn on. This value is also used
when the UPS comes out of a reboot and before the UPS
wakes up from 'sl… | scalar | RFC1155-SMITimeTicks | .1.3.6.1.4.1.318.1.1.1.5.2.9 |