upsAdvBatteryCurrentTable
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.1.2.2.14
Object
table
mandatory
A list of Battery Frame table entries. The number of entries is given by number of Battery frames present.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.1.2.2.14- Type
- table
- Status
- mandatory
- Parent
- upsAdvBattery
- Siblings
- 26
- Children
- 1
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsAdvBatteryCapacity mandatory The remaining battery capacity expressed in
percent of full capacity.
If not supported, return 0. | scalar | RFC1155-SMIGauge | .1.3.6.1.4.1.318.1.1.1.2.2.1 |
| upsAdvTotalDCCurrent mandatory The total DC current in Amps. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.2.2.10 |
| upsAdvBatteryFullCapacity mandatory The full chargeable capacity of the battery which is
expressed in percentage. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.2.2.11 |
| upsAdvBatteryActualVoltageTable mandatory A list of battery table entries. The number of battery
frames present in UPS. | table | - | .1.3.6.1.4.1.318.1.1.1.2.2.12 |
| upsAdvTotalDCCurrentTable mandatory A list of Battery Frame table entries. The number of entries
is given by the value of Number of Battery Frames. | table | - | .1.3.6.1.4.1.318.1.1.1.2.2.13 |
| upsAdvBatteryEstimatedChargeTime mandatory The estimated remaining time required to charge the UPS to a full state of charge.
If not present return maximum value(4,294,967,295). | scalar | RFC1155-SMITimeTicks | .1.3.6.1.4.1.318.1.1.1.2.2.15 |
| upsAdvBatteryPower mandatory The measured battery power in kW. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.2.2.16 |
| upsAdvBatteryChargerStatus mandatory The status of the battery charger. If the UPS is unable
to find the state of charger, this variable is set to unknown(1). | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.2.2.17 |
| upsAdvBatteryInternalSKU mandatory The SKU of the internal battery. | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.2.2.19 |
| upsAdvBatteryTemperature mandatory The current internal UPS temperature expressed in
Celsius. Temperatures below zero read as 0.
Consider using upsHighPrecExtdBatteryTemperature instead.
If not present … | scalar | RFC1155-SMIGauge | .1.3.6.1.4.1.318.1.1.1.2.2.2 |
| upsAdvBatteryExternalSKU mandatory The SKU of the external battery. | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.2.2.20 |
| upsAdvBatteryRecommendedReplaceDate mandatory The recommended replacement date for the battery based on the UPS internal battery life algorithm. | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.2.2.21 |
| upsAdvBatteryNominalBackupTime mandatory Defines the runtime of the user supplied battery in minutes, when battery is new. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.2.2.22 |
| upsAdvBatteryCondition mandatory Health of the battries based on the battery test. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.2.2.23 |
| upsAdvBatteryChargingCurrentRestricted mandatory Indicates whether battery charging current is restricted or not.
The value of yes(1) indicates that battery charging current is restricted .
The value of no(2) indicates that batt… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.2.2.24 |
| upsAdvBatteryTotalCapacity mandatory The actual available battery capacity of the system expressed in ampere hours (Ah).
The value is updated continuously, for example when battery breakers are opened or closed,
or w… | scalar | RFC1155-SMIGauge | .1.3.6.1.4.1.318.1.1.1.2.2.25 |
| upsAdvBatteryFuseStatus mandatory If battery system has one common fuse for the battery system, the status is given by this value.
1 = Fuse Open
2 = Fuse Ok
3 = Not present | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.2.2.26 |
| upsAdvBatteryBreakerStatus mandatory The value indicates the aggregated status of the battery breakers in the system.
disconnected(1) indicates none of the battery breakers are closed, and the battery system is disco… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.2.2.27 |
| upsAdvBatteryWiringConfiguration mandatory The value indicates the wiring configuration, whether the battery is 2-wire or 3-wire.
If it's a 3-wire battery system, the system can have 2 voltages and currents per cabinet.
1 … | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.2.2.28 |
| upsAdvBatteryRunTimeRemaining mandatory The UPS battery run time remaining before battery
exhaustion.
If not present return maximum value(4,294,967,295). | scalar | RFC1155-SMITimeTicks | .1.3.6.1.4.1.318.1.1.1.2.2.3 |
| upsAdvBatteryReplaceIndicator mandatory Indicates whether the UPS batteries need replacing. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.1.2.2.4 |
| upsAdvBatteryNumOfBattPacks mandatory The number of external battery packs connected to the UPS. If
the UPS does not use smart cells then the agent reports
ERROR_NO_SUCH_NAME. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.2.2.5 |
| upsAdvBatteryNumOfBadBattPacks mandatory The number of external battery packs connected to the UPS that
are defective. If the UPS does not use smart cells then the
agent reports ERROR_NO_SUCH_NAME. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.2.2.6 |
| upsAdvBatteryNominalVoltage mandatory The nominal battery voltage in Volts. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.2.2.7 |
| upsAdvBatteryActualVoltage mandatory The actual battery bus voltage in Volts.
If not supported, return -1. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.2.2.8 |
| upsAdvBatteryCurrent mandatory The battery current in Amps.
If not supported, return -1. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.1.2.2.9 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsAdvBatteryCurrentEntry mandatory An entry containing information applicable to a
particular battery frame. | row | - | .1.3.6.1.4.1.318.1.1.1.2.2.14.1 |