sPDUOutletConfigMSPgsOutletCtrlMode
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.6.6.2.1.1.5
Object
column
mandatory
Enumeration
The Control Mode of the outlet. This OID is provided for informational purposes only.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.6.6.2.1.1.5- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- sPDUOutletConfigMSPgsEntry
- Table
- sPDUOutletConfigMSPgsTable
- Siblings
- 12
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | modeGracefulShutdown |
2 | modeAnnunciator |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| sPDUOutletConfigMSPgsIndex mandatory The index to the MasterSwitch plus. | column | Integer32 | .1.3.6.1.4.1.318.1.1.6.6.2.1.1.1 |
| sPDUOutletConfigMSPgsPowerOnDelay mandatory The amount of delay, in seconds, between the UPS entering
normal (on-line) state and the outlet being powered on.
Allowed values are:
-1 - Remain Off… | column | Integer32 | .1.3.6.1.4.1.318.1.1.6.6.2.1.1.10 |
| sPDUOutletConfigMSPgsPowerOffDelay mandatory The amount of delay, in seconds, between when the server
shuts down and the outlet is powered off.
Allowed values are:
0 - 9999 seconds (0 - 2 hrs, 4… | column | Integer32 | .1.3.6.1.4.1.318.1.1.6.6.2.1.1.11 |
| sPDUOutletConfigMSPgsBattCapThresh mandatory The minimum battery capacity, as a percent (0-100%), required
of the UPS before an outlet will be allowed to power on.
Allowed values are:
0 - 100 pe… | column | Integer32 | .1.3.6.1.4.1.318.1.1.6.6.2.1.1.12 |
| sPDUOutletConfigMSPgsRebootDuration mandatory The amount of delay, in seconds, from outlet off until
outlet on during a reboot.
Allowed values are:
0 - 9999 seconds (0 - 2 hrs, 46 mins, 39 secs). | column | Integer32 | .1.3.6.1.4.1.318.1.1.6.6.2.1.1.13 |
| sPDUOutletConfigMSPgsName mandatory The name of the MasterSwitch plus. The maximum
value is 23 characters. The name is set by
using the sPDUMasterConfigMSPName OID. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.6.6.2.1.1.2 |
| sPDUOutletConfigMSPgsOutletIndex mandatory The index to the outlet entry. | column | Integer32 | .1.3.6.1.4.1.318.1.1.6.6.2.1.1.3 |
| sPDUOutletConfigMSPgsOutletName mandatory The name of the outlet. The maximum size is
23 characters. The name is set by using the
sPDUOutletConfigMSPallOutletName OID.
This OID is provided for informational purposes only. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.6.6.2.1.1.4 |
| sPDUOutletConfigMSPgsDeviceConfirm mandatory Setting this OID to deviceConfirmNo (1) cause the outlet to
NOT wait for device confirmation while performing graceful
operations.
Setting this OID to deviceConfirm… | column | Enumeration | .1.3.6.1.4.1.318.1.1.6.6.2.1.1.6 |
| sPDUOutletConfigMSPgsLowBattWarning mandatory The amount of delay, in 6 second intervals, between
when the UPS goes on battery and the power down sequence for
the outlet is initiated.
Allowed values are:
… | column | Integer32 | .1.3.6.1.4.1.318.1.1.6.6.2.1.1.7 |
| sPDUOutletConfigMSPgsLowBattMult mandatory Only applicable if sPDUOutletConfigMSPgsLowBattWarning OID is
set to -1 (On Runtime Remaining).
Allows you to set the value to stagger the shutdown sequence of the … | column | Integer32 | .1.3.6.1.4.1.318.1.1.6.6.2.1.1.8 |
| sPDUOutletConfigMSPgsRestartDelay mandatory The amount of delay, in 6 minute intervals, between
when the outlet is turned off and the outlet is turned back on
when performing a Graceful Shutdown.
Allowed valu… | column | Integer32 | .1.3.6.1.4.1.318.1.1.6.6.2.1.1.9 |