rPDUIdentHardwareRev
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.12.1.2
Object
The hardware revision of the Rack PDU. This value is set at the factory.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.12.1.2- Type
- scalar
- Access
- readonly
- Status
- mandatory
- Parent
- rPDUIdent
- Siblings
- 18
Syntax
RFC1213-MIBDisplayString
- Source
- RFC1213-MIBDisplayString
- Base type
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| rPDUIdentName mandatory The name of the Rack PDU.
The maximum string size is device dependent. | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.12.1.1 |
| rPDUIdentDeviceNumBreakers mandatory Getting this OID will return the number of circuit breakers supported by the device.
This is the same as the number of banks of outlets.
0 will be returned if the unit has no phas… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.12.1.10 |
| rPDUIdentDeviceBreakerRating mandatory Getting this OID will return rating of the circuit breakers
on the device in Amps if it has any. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.12.1.11 |
| rPDUIdentDeviceOrientation mandatory Getting this OID will return the intended physical orientation of the device.
OrientHorizonatal(1) indicates Horizontal.
OrientVertical(2) indicates Vertical. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.12.1.12 |
| rPDUIdentDeviceOutletLayout mandatory Getting this OID will return outlet layout for the device.
seqPhaseToNeutral(1) indicates outlet layout as follows:
1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,...
seqPhas… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.12.1.13 |
| rPDUIdentDeviceDisplayOrientation mandatory Getting this OID will return the intended physical orientation of the Seven-Segment Display
or LCD.
Normal(1) indicates Normal.
Reverse(2)indicates Upside-Down. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.12.1.14 |
| rPDUIdentDeviceLinetoLineVoltage mandatory Getting/Setting this OID will return/set the Line to Line Voltage.
This OID defaults to the nominal input line voltage in volts AC.
This setting is used to calculate total power a… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.12.1.15 |
| rPDUIdentDevicePowerWatts mandatory Getting this OID will return the Power in Watts. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.12.1.16 |
| rPDUIdentDevicePowerFactor mandatory Getting/setting this OID will return/set the
Power Factor in thousandths (1000 is power factor of 1).
This OID is only writable for AP7xxx SKUs
Valid range is from 0 to… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.12.1.17 |
| rPDUIdentDevicePowerVA mandatory Getting this OID will return the Power in VA. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.12.1.18 |
| rPDUIdentDeviceLinetoNeutralVoltage mandatory Getting/Setting this OID will return/set the Line to Neutral Voltage.
This OID defaults to the nominal line to neutral voltage in volts AC.
This setting is used to calculate total… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.12.1.19 |
| rPDUIdentFirmwareRev mandatory An 8-byte ID string identifying the Rack PDU firmware revision.
This value is set at the factory. | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.12.1.3 |
| rPDUIdentDateOfManufacture mandatory The date when the Rack PDU was manufactured in mm/dd/yyyy format.
This value is set at the factory. The year 2000 will be
represented by 00. | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.12.1.4 |
| rPDUIdentModelNumber mandatory A 10-character string identifying the model number of
the Rack PDU. This value is set at the factory. | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.12.1.5 |
| rPDUIdentSerialNumber mandatory A 12-character string identifying the serial number of
the Rack PDU. This value is set at the factory. | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.12.1.6 |
| rPDUIdentDeviceRating mandatory Getting this OID will return the electrical rating of the device in Amps. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.12.1.7 |
| rPDUIdentDeviceNumOutlets mandatory Getting this OID will return the number of outlets contained in the device. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.12.1.8 |
| rPDUIdentDeviceNumPhases mandatory Getting this OID will return the number of phases supported by the device. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.12.1.9 |