rPDU2DevicePropertiesDevicePowerRating
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.26.4.2.1.13
Object
column
mandatory
Integer32
The maximum power rating, measured in tenths of kilowatts, for the Rack PDU
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.26.4.2.1.13- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- rPDU2DevicePropertiesEntry
- Table
- rPDU2DevicePropertiesTable
- Siblings
- 12
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| rPDU2DevicePropertiesIndex mandatory The index to the Rack PDU properties table entry | column | Integer32 | .1.3.6.1.4.1.318.1.1.26.4.2.1.1 |
| rPDU2DevicePropertiesOrientation mandatory Rack PDU orientation | column | Enumeration | .1.3.6.1.4.1.318.1.1.26.4.2.1.10 |
| rPDU2DevicePropertiesOutletLayout mandatory Getting this OID will return outlet layout for the device.
seqPhaseToNeutral(1) indicates outlet layout as follows:
1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,...
or for single … | column | Enumeration | .1.3.6.1.4.1.318.1.1.26.4.2.1.11 |
| rPDU2DevicePropertiesMaxPhaseCurrentRating mandatory The maximum current rating, measured in Amps, for
the Rack PDU | column | Integer32 | .1.3.6.1.4.1.318.1.1.26.4.2.1.12 |
| rPDU2DevicePropertiesModule mandatory The user-defined Rack PDU numeric ID | column | Integer32 | .1.3.6.1.4.1.318.1.1.26.4.2.1.2 |
| rPDU2DevicePropertiesName mandatory A user-defined string identifying the Rack PDU | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.4.2.1.3 |
| rPDU2DevicePropertiesNumOutlets mandatory The number of outlets on the Rack PDU | column | Integer32 | .1.3.6.1.4.1.318.1.1.26.4.2.1.4 |
| rPDU2DevicePropertiesNumSwitchedOutlets mandatory The number of switched outlets on the Rack PDU | column | Integer32 | .1.3.6.1.4.1.318.1.1.26.4.2.1.5 |
| rPDU2DevicePropertiesNumMeteredOutlets mandatory The number of metered outlets on the Rack PDU | column | Integer32 | .1.3.6.1.4.1.318.1.1.26.4.2.1.6 |
| rPDU2DevicePropertiesNumPhases mandatory The number of phases present in the Rack PDU | column | Integer32 | .1.3.6.1.4.1.318.1.1.26.4.2.1.7 |
| rPDU2DevicePropertiesNumMeteredBanks mandatory The number of metered banks present in the Rack PDU | column | Integer32 | .1.3.6.1.4.1.318.1.1.26.4.2.1.8 |
| rPDU2DevicePropertiesMaxCurrentRating mandatory The maximum current rating, measured in Amps, for
the Rack PDU | column | Integer32 | .1.3.6.1.4.1.318.1.1.26.4.2.1.9 |