rARUStatusAruTotalAirflow
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.14.3.3.1.14
Object
column
mandatory
Integer32
The total airflow provided by the aru. Specified in cfm (cubic feet per minute). Can be converted to metric values using the conversion factor: 1 cfm = 1.70 m^3/hr (cubic meters per hour).
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.14.3.3.1.14- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- rARUStatusEntry
- Table
- rARUStatusTable
- Siblings
- 13
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| rARUStatusAruIndex mandatory The index to the ARU entry. | column | Integer32 | .1.3.6.1.4.1.318.1.1.14.3.3.1.1 |
| rARUStatusAruAlarmState mandatory An ASCII string containing the 8 flags representing
the current alarm state of the ARU. If the state of
the ARU is unknown, this variable is set to 'UNKNOWN'.
The f… | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.14.3.3.1.10 |
| rARUStatusAruCommStatus mandatory The state of communications to the device.
commNeverDiscovered(1) indicates there has never been communications with this device.
commsEstablished(2) indicates communication is no… | column | Enumeration | .1.3.6.1.4.1.318.1.1.14.3.3.1.11 |
| rARUStatusAruTempOvrdStatus mandatory Specifies whether the ARU is increasing airflow because
exhaust air temperature has exceeded the setting specified in the
rARUConfigAruTempOvrdSetpoint OID. | column | Enumeration | .1.3.6.1.4.1.318.1.1.14.3.3.1.12 |
| rARUStatusAruMasterControl mandatory This is the master on/off control for the ARU. | column | Enumeration | .1.3.6.1.4.1.318.1.1.14.3.3.1.13 |
| rARUStatusAruName mandatory The name of the ARU. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.14.3.3.1.2 |
| rARUStatusAruRemoteSetpoint mandatory This OID defines the desired base airflow of the ARU, or the
speed of the ARU fans when the temperature override is inactive.
See also the rARUConfigAruRemoteSetpoi… | column | Enumeration | .1.3.6.1.4.1.318.1.1.14.3.3.1.3 |
| rARUStatusAruManualSetpoint mandatory Manual operating setpoint of the ARU, which is set on the
panel of the ARU. If the ARU doesn't have a manual ,
the OID will always return a value of aruRem (10).
NO… | column | Enumeration | .1.3.6.1.4.1.318.1.1.14.3.3.1.4 |
| rARUStatusAruTemp1 mandatory ARU temperature probe #1 reading.
The summary exhaust temperature on 2nd generation ARUs.
NOTE: -1 will be returned if the ARU is not communicating.
… | column | Integer32 | .1.3.6.1.4.1.318.1.1.14.3.3.1.5 |
| rARUStatusAruTemp2 mandatory ARU temperature probe #2 reading.
The exhaust temperature in the upper plenum on 2nd generation ARUs.
NOTE: -1 will be returned if the ARU is not communicating.
… | column | Integer32 | .1.3.6.1.4.1.318.1.1.14.3.3.1.6 |
| rARUStatusAruTemp3 mandatory ARU temperature probe #3 reading.
The exhaust temperature in the lower plenum on 2nd generation ARUs.
NOTE: -1 will be returned if the ARU is not communicating.
… | column | Integer32 | .1.3.6.1.4.1.318.1.1.14.3.3.1.7 |
| rARUStatusAruTempOvrdEnableDisable mandatory This OID indicates whether the ARU remote temperature override is enabled or disabled.
If this OID is a 1, the remote setting for temperature override is disabled.
If this OID is … | column | Enumeration | .1.3.6.1.4.1.318.1.1.14.3.3.1.8 |
| rARUStatusAruTempOvrdSetpoint mandatory ARU remote temperature override setpoint setting.
NOTE: -1 will be returned if the ARU is not communicating.
Values are represented in whole number d… | column | Integer32 | .1.3.6.1.4.1.318.1.1.14.3.3.1.9 |