rARUStatusAruTemp3
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.14.3.3.1.7
Object
column
mandatory
Integer32
ARU temperature probe #3 reading.
The exhaust temperature in the lower plenum on 2nd generation ARUs.
NOTE: -1 will be returned if the ARU is not communicating.
Values are represented in whole number degrees.
Units are displayed in the scale shown in
the rARUStatusSysTempUnits OID (Celsius or Fahrenheit).
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.14.3.3.1.7- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- rARUStatusEntry
- Table
- rARUStatusTable
- Siblings
- 13
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| rARUStatusAruIndex mandatory The index to the ARU entry. | column | Integer32 | .1.3.6.1.4.1.318.1.1.14.3.3.1.1 |
| rARUStatusAruAlarmState mandatory An ASCII string containing the 8 flags representing
the current alarm state of the ARU. If the state of
the ARU is unknown, this variable is set to 'UNKNOWN'.
The f… | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.14.3.3.1.10 |
| rARUStatusAruCommStatus mandatory The state of communications to the device.
commNeverDiscovered(1) indicates there has never been communications with this device.
commsEstablished(2) indicates communication is no… | column | Enumeration | .1.3.6.1.4.1.318.1.1.14.3.3.1.11 |
| rARUStatusAruTempOvrdStatus mandatory Specifies whether the ARU is increasing airflow because
exhaust air temperature has exceeded the setting specified in the
rARUConfigAruTempOvrdSetpoint OID. | column | Enumeration | .1.3.6.1.4.1.318.1.1.14.3.3.1.12 |
| rARUStatusAruMasterControl mandatory This is the master on/off control for the ARU. | column | Enumeration | .1.3.6.1.4.1.318.1.1.14.3.3.1.13 |
| rARUStatusAruTotalAirflow mandatory The total airflow provided by the aru. Specified in cfm (cubic feet per minute).
Can be converted to metric values using the conversion factor:
1 cfm = 1.70 m^3/hr (cubic meters p… | column | Integer32 | .1.3.6.1.4.1.318.1.1.14.3.3.1.14 |
| rARUStatusAruName mandatory The name of the ARU. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.14.3.3.1.2 |
| rARUStatusAruRemoteSetpoint mandatory This OID defines the desired base airflow of the ARU, or the
speed of the ARU fans when the temperature override is inactive.
See also the rARUConfigAruRemoteSetpoi… | column | Enumeration | .1.3.6.1.4.1.318.1.1.14.3.3.1.3 |
| rARUStatusAruManualSetpoint mandatory Manual operating setpoint of the ARU, which is set on the
panel of the ARU. If the ARU doesn't have a manual ,
the OID will always return a value of aruRem (10).
NO… | column | Enumeration | .1.3.6.1.4.1.318.1.1.14.3.3.1.4 |
| rARUStatusAruTemp1 mandatory ARU temperature probe #1 reading.
The summary exhaust temperature on 2nd generation ARUs.
NOTE: -1 will be returned if the ARU is not communicating.
… | column | Integer32 | .1.3.6.1.4.1.318.1.1.14.3.3.1.5 |
| rARUStatusAruTemp2 mandatory ARU temperature probe #2 reading.
The exhaust temperature in the upper plenum on 2nd generation ARUs.
NOTE: -1 will be returned if the ARU is not communicating.
… | column | Integer32 | .1.3.6.1.4.1.318.1.1.14.3.3.1.6 |
| rARUStatusAruTempOvrdEnableDisable mandatory This OID indicates whether the ARU remote temperature override is enabled or disabled.
If this OID is a 1, the remote setting for temperature override is disabled.
If this OID is … | column | Enumeration | .1.3.6.1.4.1.318.1.1.14.3.3.1.8 |
| rARUStatusAruTempOvrdSetpoint mandatory ARU remote temperature override setpoint setting.
NOTE: -1 will be returned if the ARU is not communicating.
Values are represented in whole number d… | column | Integer32 | .1.3.6.1.4.1.318.1.1.14.3.3.1.9 |