pcnsShutdown
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.2.3.5
Object
node
No description available.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.2.3.5- Type
- node
- Parent
- powerChuteNetworkShutdown
- Siblings
- 6
- Children
- 9
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pcnsIdent | node | - | .1.3.6.1.4.1.318.1.2.3.1 |
| pcnsNetworking | node | - | .1.3.6.1.4.1.318.1.2.3.2 |
| pcnsNMC | node | - | .1.3.6.1.4.1.318.1.2.3.3 |
| pcnsEvents | node | - | .1.3.6.1.4.1.318.1.2.3.4 |
| pcnsAlarms | node | - | .1.3.6.1.4.1.318.1.2.3.6 |
| pcnsLoggingLevel mandatory Override the Root Logging level for PCNS. Possible Values: CLEAR, DEBUG | scalar | OctetString | .1.3.6.1.4.1.318.1.2.3.7 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pcnsShutdownCommandFileEnabled mandatory Run a shutdown command file before performing graceful shutdown. | scalar | Enumeration | .1.3.6.1.4.1.318.1.2.3.5.1 |
| pcnsShutdownCommandFileDelay mandatory How long in seconds to wait before running a shutdown command file before graceful shutdown. | scalar | Integer32 | .1.3.6.1.4.1.318.1.2.3.5.2 |
| pcnsShutdownCommandFile mandatory Full name of the shutdown command file to run before graceful shutdown. | scalar | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.2.3.5.3 |
| pcnsShutdownCommandFileDuration mandatory How long in seconds shutdown command file takes to run. | scalar | Integer32 | .1.3.6.1.4.1.318.1.2.3.5.4 |
| pcnsTurnOffUps mandatory Turn off the UPS when performing a graceful shutdown. | scalar | Enumeration | .1.3.6.1.4.1.318.1.2.3.5.5 |
| pcnsTurnOffSOG mandatory Turn off the Outlet Group on the UPS when performing a graceful shutdown. | scalar | Enumeration | .1.3.6.1.4.1.318.1.2.3.5.6 |
| pcnsRuntimeRemainingThreshold mandatory This defines a threshold for runtime remaining. When the
UPS is running on battery power and the runtime remaining
on the UPS drops below the threshold, PowerChute will trigger
a … | scalar | Integer32 | .1.3.6.1.4.1.318.1.2.3.5.7 |
| pcnsRuntimeRemainingCmdFileThreshold mandatory This defines a threshold for runtime remaining. When
runtime remaining drops below this threshold, PowerChute
will execute the command file. | scalar | Integer32 | .1.3.6.1.4.1.318.1.2.3.5.8 |
| pcnsAdvancedShutdownTable mandatory The Network Management Cards in the UPS devices, which PCNS is monitoring to provide safe shutdown. | table | - | .1.3.6.1.4.1.318.1.2.3.5.9 |