memInputAnalogCalibrationPoint2Value
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.10.4.3.4.1.16
Object
The value of the input, in units of measure defined by the user, that corresponds to the current setting at the second calibration point.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.10.4.3.4.1.16- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- memInputsConfigEntry
- Table
- memInputsConfigTable
- Siblings
- 24
Syntax
RFC1213-MIBDisplayString
- Source
- RFC1213-MIBDisplayString
- Base type
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| memInputsConfigModuleNumber mandatory The number of the module that the input is attached to. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.1 |
| memInputAnalogCalibrationPoint1 mandatory The electrical value that the input sensor will measure at the
first calibration point.
This OID is relevant only for inputs configured as analog type (ma or V). | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.10 |
| memInputAnalogCalibrationPoint2 mandatory The electrical value that the input sensor will measure at the
second calibration point.
This OID is relevant only for inputs configured as analog type (ma or V). | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.11 |
| memInputAnalogCalibrationPoint3 mandatory The electrical value that the input sensor will measure at the
third calibration point.
This OID is relevant only for inputs configured as analog type (ma or V). | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.12 |
| memInputAnalogCalibrationPoint4 mandatory The electrical value that the input sensor will measure at the
fourth calibration point.
This OID is relevant only for inputs configured as analog type (ma or V). | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.13 |
| memInputAnalogCalibrationPoint5 mandatory The electrical value that the input sensor will measure at the
fifth calibration point.
This OID is relevant only for inputs configured as analog type (ma or V). | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.14 |
| memInputAnalogCalibrationPoint1Value mandatory The value of the input, in units of measure defined by
the user, that corresponds to the current setting at the
first calibration point. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.15 |
| memInputAnalogCalibrationPoint3Value mandatory The value of the input, in units of measure defined by
the user, that corresponds to the current setting at the
third calibration point. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.17 |
| memInputAnalogCalibrationPoint4Value mandatory The value of the input, in units of measure defined by
the user, that corresponds to the current setting at the
fourth calibration point. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.18 |
| memInputAnalogCalibrationPoint5Value mandatory The value of the input, in units of measure defined by
the user, that corresponds to the current setting at the
fifth calibration point. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.19 |
| memInputsConfigInputNumber mandatory The number of this input on the module. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.2 |
| memInputAnalogMeasurementUnits mandatory The units of measure to be used for this input. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.20 |
| memInputAnalogMaxThresh mandatory The input value at which a maximum threshold violation
alarm will be generated on this input. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.21 |
| memInputAnalogHighThresh mandatory The input value at which a high threshold violation
alarm will be generated on this input. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.22 |
| memInputAnalogLowThresh mandatory The input value at which a low threshold violation
alarm will be generated on this input. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.23 |
| memInputAnalogMinThresh mandatory The input value at which a minimum threshold violation
alarm will be generated on this input. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.24 |
| memInputAnalogThreshHysteresis mandatory The change in value required to cause an alarm on this input
to change from active to inactive. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.25 |
| memInputName mandatory The name of the input. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.3 |
| memInputLocation mandatory The location of the input. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.4 |
| memInputType mandatory The type of input this contact will take. | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.5 |
| memInputAlarmGeneration mandatory Enable or disable alarm generation on this input. | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.6 |
| memInputNormalState mandatory Defines the normal (no alarm) state of the input. | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.7 |
| memInputAbnormalSeverity mandatory Defines the severity of the event that is associated
with the abnormal state of the input. This OID will return
inputSeverityNotApplicable(4) for analog input types. | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.8 |
| memInputNumberCalibrationPoints mandatory The number of calibration points that are required for
this input. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.9 |